background image

 
 

Instruction Manual DPY351_R11 

Page 5 

6.3.2 

CAN Communication  

 

Aux3:  

RJ45  

Supported Protocols 

J1939 
Raw CAN 
Can Open 

Supported Baud Rate 
(Factory setting: xxxxxx) 

50 Kbit/s, 100 Kbit/s, 125 
Kbit/s, 250 Kbit/s, 500 Kbit/s, 
800 Kbit/s, 1 Mbit/s, 

Internal Terminating Resistor (120 
Ω) 
(Factory Setting OFF) 

Configurable by Switch Aux6 
(Section: Hardware 
configurations Can) 

6.4 

Ambient Conditions 

Ambient Temperature operation 

-25 up to +70 °C 

Ambient Temperature Storage 

-40 up to +85 °C 

Humidity at 25 °C, no condensation  95 % to 25 °C 
Vibration (operation) IEC 60068-2-

<15 Hz, amplitude 

 

2.5mm<15Hz-150Hz, 2.3G 90 
min. 

Shock IEC 60068-2-6 

30g in all directions 

6.5 

General Data 

Protection Class (EN/IEC 60529)  

Front panel only IP65; Rear 
IP22 

Reliability: MTBF IEC 61709  

> 700.000 h (Automatically 
Switch Off Beck Light after 30 
sec) 

Aux5 Connection Terminal Blocks 
Push Button Type 

Wire diameter Ø: 0.05 mm 
(30AWG) - 1.5 mm (14AWG) 

 

Protection class 

II  

Housing material 

Polycarbonate 

Dimension (w-h-d) mm 

112 x 117 x 52 

Weight 

0.35 kg approx.  

Hole 

90 mm 

Available Languages 

English 

Automatic Power ON 

Deep Switch 4 ON (Aux6) 

6.6 

Accessory 

Connector Cable RJ45/RJ45 1m 
for CBI Size 4 

RJCONN45 

Connector Cable RJ45/RJ45 1m 
for CBI (Device Size 3) 

DPYCONN500 

RJTEMP111 or 113 

Temp. Environment Sensor 

Shunt 50 (for Device Size 3) 

Measure the Load current 

6.7 

Hardware Port  

6.7.1 

Digital Input ports “Aux5” 

Input: 

N° 2 

Application Pins 

Pins 3,4 

Minimum Voltage for Low Level: 

0-72 V, user-configurable 

Minimum Voltage for High Level: 

0-72 V, user-configurable 

6.7.2 

Analog Input ports “Aux5”  

Input: 

N° 1 

Application Pin 

Pins 5,6 

For Shunt connection 

50 A 

6.7.3 

Output port “Aux5” 

Output 

N° 1 

Application Pin 

Pins 7,8 

Output Type 

Dry Contact (NO) 

Max. current can be switched (EN60947.4.1): 
Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A  (Resistive Load) 
Min.1mA at 5 Vdc  (Min. Load) 

 

6.8 

Software Port 

6.8.1 

Remote Monitoring “Ethernet Connection” 

IP (Static) 

192.168.1.100 

User 

admin 

PW 

admin 

6.8.2 

Web Server  

User friendly operation trough monitoring and configuration on one 
page 
Independent identification of individual modules, a system 
configuration it is not necessary 
Integrated access management: access can be individually 
determined locally and centrally 
Integrated data storage, each modification and each error can be 
recorded 

6.9 

Norms and certifications 

6.9.1 

Immunity and Emission 

The CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility 
Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction 
of the use of certain Hazardous Substances in Electrical and Electronic 
Equipment (RoHS), as amended by 2015/863/EU 

 

EMC Immunity: EN61000-6-2 

 

EMC Emission: EN61000-6-3  

6.10 

Electrical Safety for mounting 

According to: 

 

Electrical Equipment for Machinery EN 60204 

 

Electrical  safety  (of  information  technology  equipment)  IEC/EN 
EN62368-1. 

 

Safety  requirements  for  electrical  equipment  for  measurement, 
control and Laboratory use IEC/EN 61010 

6.10.1 

Environmental Norm Conditions 

 

Degrees of protection provided by enclosures IEC/EN 60529 
IP65:  

o

 

First  Digit:  Protection  against  ingress  of  durst  (durst 
tight). Complete protection against contact. 

o

 

Second Digit: Protection against water projected from a 
nozzle  against  the  equipment  (enclosure)  from  any 
direction. There must be no harmful effect (water jet) 

 

Environmental Testing IEC/EN 60068 

7.1  Annex 1: Mounting template

Reviews: