Instruction Manual DPY351_R11
Page 5
6.3.2
CAN Communication
Aux3:
RJ45
Supported Protocols
J1939
Raw CAN
Can Open
Supported Baud Rate
(Factory setting: xxxxxx)
50 Kbit/s, 100 Kbit/s, 125
Kbit/s, 250 Kbit/s, 500 Kbit/s,
800 Kbit/s, 1 Mbit/s,
Internal Terminating Resistor (120
Ω)
(Factory Setting OFF)
Configurable by Switch Aux6
(Section: Hardware
configurations Can)
6.4
Ambient Conditions
Ambient Temperature operation
-25 up to +70 °C
Ambient Temperature Storage
-40 up to +85 °C
Humidity at 25 °C, no condensation 95 % to 25 °C
Vibration (operation) IEC 60068-2-
6
<15 Hz, amplitude
2.5mm<15Hz-150Hz, 2.3G 90
min.
Shock IEC 60068-2-6
30g in all directions
6.5
General Data
Protection Class (EN/IEC 60529)
Front panel only IP65; Rear
IP22
Reliability: MTBF IEC 61709
> 700.000 h (Automatically
Switch Off Beck Light after 30
sec)
Aux5 Connection Terminal Blocks
Push Button Type
Wire diameter Ø: 0.05 mm
(30AWG) - 1.5 mm (14AWG)
Protection class
II
Housing material
Polycarbonate
Dimension (w-h-d) mm
112 x 117 x 52
Weight
0.35 kg approx.
Hole
90 mm
Available Languages
English
Automatic Power ON
Deep Switch 4 ON (Aux6)
6.6
Accessory
Connector Cable RJ45/RJ45 1m
for CBI Size 4
RJCONN45
Connector Cable RJ45/RJ45 1m
for CBI (Device Size 3)
DPYCONN500
RJTEMP111 or 113
Temp. Environment Sensor
Shunt 50 (for Device Size 3)
Measure the Load current
6.7
Hardware Port
6.7.1
Digital Input ports “Aux5”
Input:
N° 2
Application Pins
Pins 3,4
Minimum Voltage for Low Level:
0-72 V, user-configurable
Minimum Voltage for High Level:
0-72 V, user-configurable
6.7.2
Analog Input ports “Aux5”
Input:
N° 1
Application Pin
Pins 5,6
For Shunt connection
50 A
6.7.3
Output port “Aux5”
Output
N° 1
Application Pin
Pins 7,8
Output Type
Dry Contact (NO)
Max. current can be switched (EN60947.4.1):
Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A (Resistive Load)
Min.1mA at 5 Vdc (Min. Load)
6.8
Software Port
6.8.1
Remote Monitoring “Ethernet Connection”
IP (Static)
192.168.1.100
User
admin
PW
admin
6.8.2
Web Server
User friendly operation trough monitoring and configuration on one
page
Independent identification of individual modules, a system
configuration it is not necessary
Integrated access management: access can be individually
determined locally and centrally
Integrated data storage, each modification and each error can be
recorded
6.9
Norms and certifications
6.9.1
Immunity and Emission
The CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility
Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction
of the use of certain Hazardous Substances in Electrical and Electronic
Equipment (RoHS), as amended by 2015/863/EU
EMC Immunity: EN61000-6-2
EMC Emission: EN61000-6-3
6.10
Electrical Safety for mounting
According to:
Electrical Equipment for Machinery EN 60204
Electrical safety (of information technology equipment) IEC/EN
EN62368-1.
Safety requirements for electrical equipment for measurement,
control and Laboratory use IEC/EN 61010
6.10.1
Environmental Norm Conditions
Degrees of protection provided by enclosures IEC/EN 60529
IP65:
o
First Digit: Protection against ingress of durst (durst
tight). Complete protection against contact.
o
Second Digit: Protection against water projected from a
nozzle against the equipment (enclosure) from any
direction. There must be no harmful effect (water jet)
Environmental Testing IEC/EN 60068
7.1 Annex 1: Mounting template