REMOTE KEYPADS

 6150PL3 & 6160PL3

INSTALLATION GUIDE

Keypad Features

6150PL3

Fixed-Word

6160PL3

2-Line Alpha

Backlit Display

YES (See Note 1)

YES (See Note 1)

Dedicated Function Keys

YES

YES

Built-in Sounder

Piezo

Speaker

Notes1.Permanent display backlighting is an option on some controls (see the control's instructions for details).

GENERAL INFORMATION

WIRING AND INSTALLATION

The 6150PL3 and 6160PL3 are addressable Remote
Keypads designed for use with SecurityLink control panels.
Addresses are set via the keypad keys.

The keys on the keypads are continuously backlit for
convenience.

KEYPAD DISPLAYS AND LEDS

The keypads have the following display features:

Model

Fixed

Word

Display

2-line

Alpha

Display

2-digit

Zone

Identifier

Custom

Zone

Descriptors

6150PL3

X

X

6160PL3

X

X

The following table shows the LEDs and their functions:

LED

Function

Red

Lights when the system is armed in any mode

Green

Lights when the system is "ready" to be armed.

SPECIAL FUNCTION KEYS

The keypads also feature function keys.  These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.

Function Key

Corresponding Key

Pair

A

[1]  &  [*]

B

[*]  &  [#]

C

[3]  &  [#]

D

NONE

The keypads can be surface mounted directly to a drywall, or to
a single- or double-gang electrical box.

1.

 

Remove the case back by pushing down two "snaps."
See diagram below.

2.

 

Route wiring from the control panel through the
opening in the case back.

3.

 

Mount the case back to a wall or electrical box.

4.

 

Wire directly from the keypad’s terminal block to the
terminal block on the control board.  Wire functions are
marked next to terminals.  Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel.  See the control panel’s Installation
Instructions for more complete details.

5.

 

Re-attach the keypad to its case back.

1

2

3

6

5

4

8

9

7

0

*

#

OFF

AWAY

STAY

MAX

TEST

BYPASS

INSTANT

CODE

CHIME

READY

ARMED

READY

A

B

C

D

MOUNTING RELEASE SNAPS

(Remove case back by pushing

up the 2 "snaps" along the
keypad's bottom edge and

pulling the case apart.)

SIDE VIEW

Function keys must be held down for at
least 2 seconds to activate an alarm, key
pairs activate immediately.