background image

Summary of Contents for Vista-50

Page 1: ...N5943 4Vl 11I94 VISTAm50 VISTA 5OUL Previous Menu...

Page 2: ...ZONE DESCRIPTORS 21 BYPASSING PROTECTION ZONES 22 Quick Bypass 23 Displaying Bypassed Protection Zones 23 ARMING PERIMETER ONLY STAY 24 ARMING PERIMETER ONLY INSTANT 25 ARMING ALL PROTECTION AWAY 26...

Page 3: ...y placed smoke or combustion detectors designed to provide early warning in case of fire The system uses microcomputer technology to monitor all protection zones and system status and provides appropr...

Page 4: ...ense burglary alarm conditions Your system provides four modes of burglary protection STAY AWAY INSTANT and MAXIMUM and even allows you to BYPASS selected zones of protection while leaving the rest of...

Page 5: ...n alarm occurs both the console and external sounders will sound and the console will display the zone s causing the alarm If your system is connected to a central monitoring station an alarm message...

Page 6: ...hat can be controlled are programmed into the system by the installer Up to 16 of these devices can be programmed Refer to the PROGRAMMING DEVICE TIMERS section for procedures To Access Another Each c...

Page 7: ...FUNCTIONS OF THE CONSOLE section for descriptions of each key function Phone Access Your system may include a voice module that will permit you to access the system via a Voice Touch tone phone eithe...

Page 8: ...system to acknowledge the key press These sounds can be optionally suppressed in some of your consoles so as not to disturb other users of the system Ask your installer if this has been done There are...

Page 9: ...feature is activated Low battery condition in a wireless sensor if ID number displayed or low system battery if no ID number displayed Appears when an intrusion has been detected and the system is ar...

Page 10: ...monitored by the system Displays previously bypassed protection zcnes 1 KEY Armsin mannersimilart STAY mode butturns offthaentrydelaypertod offering greatersecurity whileinsideandnot expectingany late...

Page 11: ...ated otherwise most procedures in this manual apply to all console types and styles Some procedures however are specifically intended for use by alpha consoles only Tf Wh en using the keypad to enter...

Page 12: ...will sound throughout the exit delay period Entry Delay gives you time to disarm the system when you reenter through the designated entrance door But the system must be disarmed before the entry dela...

Page 13: ...ctions within the limits of each code s authority level a system armed with one user s code can be disarmed by another user s code with the exception of the Operator Level C code See AUTHORITY LEVELS...

Page 14: ...r level users Level 3 Operator A Can perform system functions in assigned partitions but cannot add or delete other users Level 4 Operator B Same as Operator A except Operator B cannot bypass zones of...

Page 15: ...A user can only be DELETED or CHANGED from within the partition he is assigned User numbers must be entered as 2 digit entries Single digit user numbers must be preceded by a O example 03 04 etc Secu...

Page 16: ...no 1 YES I EYE 1 Enter 1 to add a new user code Entering O will change the existing user s code to the code entered in step 3 See Changing A User s Code section Enter the authority level 1 6 for this...

Page 17: ...yes the system will automatically assign a user number for use in that partition and will prompt for the authority level and global arm option for this user within the partition see previous steps R...

Page 18: ...or the new code to be reentered This prevents accidentally changing a high level code CODE To Delete a 1 Enter Master or Manager code and press the key User Number to be deleted User 2 Enter Master or...

Page 19: ...ber Owill return the console to its original partition 2 eypadactivi The console will remain in the new partition until directed to go to another partition or until 2 minutes has elapsed with no AAAA...

Page 20: ...te Some consoles light a green LED when the system is ready If not lit the system is not ready to be armed READY 1 Do not enter security code but simply press EE 1 Typical fault display 2 LZZEI Secure...

Page 21: ...ted instructions for the READY key will appear first followed by the zone descriptors Displaying all descriptors is useful when you need to know the zone number of a particular zone as when bypassing...

Page 22: ...ency zones to be bypassed To bypass zones the system must be disarmed first 1 2 BYPASS Enter your security code and press Enter zone number s for the zones to be bypassed e g 01 02 03 etc Important Al...

Page 23: ...all open zones will be displayed along with the word BYPASS Wait for these zones to be displayed before arming Arming the system before bypassed zones are displayed eliminates all bypasses Arm the sy...

Page 24: ...remises Late arrivals can enter through the entrance door without causing an alarm but they must disarm the system within the entry delay period or an alarm will occur Close all perimeter windows and...

Page 25: ...u may otherwise move freely throughout the premises The alarm will also sound immediately if anyone opens the entrance door Close all perimeter windows and doors before arming see CHECKING FOR OPEN ZO...

Page 26: ...ce door during the exit delay period without causing an alarm You may also reenter through the entrance door but must disarm the system within the entry delay period or an alarm will occur Close all p...

Page 27: ...window is opened or if any movement is detected inside the premises You may leave through the entrance door during the exit delay period without causing an alarm but an alarm will be sounded as soon a...

Page 28: ...the system and silence burglary or fire alarms OFF 1 Enter your security code and press EiEl The Ready message will be displayed if no alarms have occurred while armed and the console will beep once t...

Page 29: ...system is armed or memory of alarm exists Lit Steady System is armed in AWAY mode Slow Flashing System is armed in STAY mode Rapid Flashing Memory of alarm indicating an alarm has occurred To arm in...

Page 30: ...ed only when the system is disarmed CHIME 1 To turn Chime Mode on enter the security code and press m The CHIME MODE ON message will appear for about two seconds then disappear To display this message...

Page 31: ...essages on their display screens from Information their monitoring agency or installer When a message is waiting to be viewed the message shown below will appear 1 Press and hold down key for 5 second...

Page 32: ...ge to the central station if 3 and 96 connected and will sound a loud steady alarm at and 99 your console and at any external sounders that A 95 may be connected ALARM plus a zone B 99 number would al...

Page 33: ...uch that a locked access door such as in a lobby can be Information unlocked using a console command Ask your installer if this has been done in your system To activate this relay 1 Enter your securit...

Page 34: ...digit number of the device to be activated Note that if an invalid number is entered the system will simply ask you to reenter the number ml Voice voicedescriptor DEVICE nn ON OFF FOR voice descriptor...

Page 35: ...thority levels only 2 Press the key followed by 82 3 A menu prompt will be displayed asking for the number of hours of delay m Enter the desired number of hours of delay 1 or 2 The system will automat...

Page 36: ...ng closing time window and a disarming opening time window A time window is simply a defined period of time at the end of which arming or disarming will occur Before programming a temporary schedule u...

Page 37: ...The following prompts will appear Mon ARM WINDOW 07 45AM 08 45AM I The cursor will be positioned on the tens of hours digit of the start time for Monday s disarm window Enter the desired hour Press t...

Page 38: ...temporary schedule to be customized to a particular week s needs To select the days which are to be activated enter the desired number 1 7 Monday 1 An X will appear under that day indicating the previ...

Page 39: ...n control the same device For example timer 2 could be used Monday Friday as in the previous example and timer 3 could be set to turn the air conditioner on and off at different times Saturday and Sun...

Page 40: ...00 if this timer is not being used to turn something OFF for the days selected below ex using one timer to turn lights on one day and using another timer to turn them off on another day Select the da...

Page 41: ...r 3 seconds and then turn off If the sounder does not sound it maybe due to dialer communication activity Wait a few minutes and try again If the sounder still does not sound CALL FOR SERVICE IMMEDIAT...

Page 42: ...splay when it is activated Follow the manufacturer s instructions to test all smoke detectors to ensure that all are functioning properly The identification of each detector or the zone number of the...

Page 43: ...e zone s displayed are intact and make them so if they are not If the problem has been corrected the display of the zone descriptor s and CHECK should disappear If not key an OFF sequence Code plus OF...

Page 44: ...nd reset or replace as necessary CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored The following displays will appear on non alpha consoles when the associated trouble condition previously d...

Page 45: ...2 seconds Evacuate all occupants from the premises If flames and or smoke are present leave the premises and notify your local Fire Department immediately If no flames or smoke are apparent investiga...

Page 46: ...ws A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding...

Page 47: ...plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes...

Page 48: ...ervice Actual battery life will depend on the environment in which the sensor is used the number of signals that the transmitter in the sensor has had to send and the specific type of sensor Factors s...

Page 49: ...signal to the control as soon as the sensor is activated opening closing of door window etc causing the low battery display to turn off If the sensor is not activated the display WIIIautomatically cle...

Page 50: ...s Enter code Press CHIME 9 Enter code Press TEST 5 Press and hold 0 for at least 5 seconds Enter user s code Press COMMENTS To view faulted zones when system not ready Displays all alpha descriptors p...

Page 51: ...user At prompt enter authority for that user in this partition 1 5 Follow prompts 1 Yes O NO Change a user s Enter master manager code Master Manager level users can change their own or other Code Pre...

Page 52: ...ANT a ARMtD ONe BYPASSkD Console only is displayed Red ARMED indicator is b ZONE OPENED WHILE SYSTEM b CHIME displayed descriptor of open protection zone will be displayed ifthe x IS IN CHIME MODE ke...

Page 53: ...ual ZONE A specific area of protection PARTITION An independent group of zones that can be armed and disarmed without affecting other zones or users BYPASS To disarm a specific area of burglary protec...

Page 54: ...receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the f...

Page 55: ...al the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe necessary The telephone company may make ch...

Page 56: ...est corrforme a certaines normes de protection d exploitation et de securite des rt eaux de t ldcommunicafions Le ministbre n assure toutefois oas oue Ie mak riel forvctionneraa la satisfactionde I uf...

Page 57: ...stalled and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors...

Page 58: ...tem responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not re...

Page 59: ...s Name and Address hsuranceCcmpany Mcy No ADEMCO S VISTA 50 Other Type of Alarm Burglary m Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire LocalSoundi...

Page 60: ...Room F BURGLARY DETECTING DEVICE LOCATIONS m FrontDoor D Basement Door Rear Door lst Floor Windows All windows Interior locations D All Accessible Openings lncluding Swlights Air Conditioners and Vent...

Page 61: ...a User 18 descriptors 21 Device Timers 6 39 disarm 28 Duress 14 Duress Code 13 E emergency 3 EMERGENCYEVACUATION 47 Entry Delay 12 Entry Exit 4 exit delay 12 Exit User Edit Mode 15 F FC 44 fire 3 9 32...

Page 62: ...Batteries 48 s schedules 6 35 security code 13 SECURITY CODES 13 sensing ctevices 4 Silence thealarm 45 Silent Emergency 32 smoke detectors 42 Stay 4 9 19 24 29 SYSTEM LO BAT 43 T Temporary schedules...

Page 63: ...on of displaying the COMPLETE log or only those events occurring since the last installer service RECENT In addition events in the other partitions can be viewed by users authorized to access those pa...

Page 64: ...time EmKl ALARM EVENT LOG Displays time and date for zones that have either caused an alarm or have been restored in the selected partition CHECK EVENT LOG Displays time and date for zones that have...

Page 65: ...ASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE...

Page 66: ...XDEMCO N5943 4Vl 11194 ALARM DEVICE MANUFACTURING CORPORATION A DIVISION OF PIllWAY CORPORATION 165 Eileen Way Syosset New York 11791 Copyright 0 1994 PIllWAY CORPORATION...

Reviews: