Section 20 – Zone Type Definitions
20-3
Type 10: Interior with Delay
Provides entry and exit delays (using the programmed entry/exit time), if tripped when the
panel is armed in the AWAY mode and exit delay only when armed in MAXIMUM mode.
Interior with Delay zones are automatically bypassed when the panel is armed in
the STAY or INSTANT mode. Delay begins whenever sensors in this zone are violated,
regardless of whether or not an entry/exit delay zone was tripped first.
Assign this zone type to a zone covering an area such as a foyer, lobby, or hallway through
which one must pass upon entry or exit (to and from the keypad).
Type 20: Arm-STAY
✳
Causes the system to arm in the STAY mode when the zone is activated.
Type 21: Arm-AWAY
✳
Causes the system to arm in the AWAY mode when the zone is activated.
Type 22: Disarm
✳
Causes the system to disarm when the zone is activated.
Type 23: No Alarm Response
Used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
for lobby door access).
Type 27: Access Point
Indicates that an input device (hardwired zone, wireless zone, keypad, access control relay,
etc.) is controlling an access point entry (e.g., a door). The access point entry relay can be
assigned to an access control relay (controlled by the VISTA-50PEN), ECP relay (4204), or to
the access control system independent of the VISTA-50PEN.
Type 28: Main Logic Board (MLB) Supervision
Used to supervise the MLB. If communication between the MLB and the Vista Gateway
Module (VGM) fails, a trouble condition is annunciated for the zone. Also, if the
communication fails, all access control system (ACS) input zones will also display a
“CHECK.”
Type 29 Momentary on Exit
Used to cause an access point programmed for entry to revert to an exit point for 15 seconds.
After the 15 seconds it automatically reverts back to an entry point. This zone type should be
only used with VistaKey modules.
✳
Note that these zone types are for use by 5800 Series devices only!
NOTE FOR PANIC KEYS: Keypad panic zones share the same zone response type for all 8
partitions, but panics may be individually enabled for each partition.
IMPORTANT! FAULT ANNUNCIATION
Polling loop and RF troubles (zones 988, 990 & 997) will report as trouble conditions only, and as
such, should be assigned zone type 05 if annunciation is desired. See
Polling Loop Supervision
in the
2-Wire Polling Loop Expansion
section and
RF System Operation and Supervision
in the
Wireless Expansion
section for more information.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...