Section 22 – Data Field Descriptions
22-5
*37
DOWNLOAD COMMAND ENABLES
Dialer
Shutdown
System
Shutdown
Not
Used
Remote
Bypass
Remote
Disarm
Remote
Arm
Upload
Program
Download
Program
Each of the various remote functions can either be enabled or disabled through Compass
downloading software. Disabling a function means that you will not be able to perform
that function from Compass. Default values = [11011111].
Enter 1 to enable a function, enter 0 to disable. See field 1*53 to disable the download
callback option. For UL commercial burglary installations, all entries must be 0.
*38
PREVENT ZONE XXX BYPASS (partition-specific)
[000]
|
|
Entering a zone number (001-128) prevents that zone from being bypassed by the user.
Enter 000 if this feature is not desired (all zones can be bypassed).
*39
ENABLE OPEN/CLOSE REPORT FOR INSTALLER CODE(partition-specific)
[1]
Enter 1 if Open/Close reporting for the installer is desired.
Otherwise enter 0.
*40
OPEN/CLOSE REPORTING FOR KEYSWITCH
[0]
Enter 1 to enable Open/Close reporting for the keyswitch.
Enter 0 if reporting is not desired.
*41
NORMALLY CLOSED OR EOLR (ZONES 2-8)
[0]
Enter 0 if end-of-line resistors are to be used.
Enter 1 if end-of-line resistors are not to be used, in which case only normally closed
devices must be used.
Must be 0 for UL installations.
*42
DIAL TONE PAUSE
[0]
This field sets the time the system will wait for dial tone before dialing. Applies if true
dial tone is not selected in field *43.
Enter the desired wait time for dial tone detection as follows: Enter single digit: 0 = 5
seconds; 1 = 11 seconds; or 2 = 30 seconds. Must be 0 for UL installations.
*43
DIAL TONE DETECTION
[1]
Determines whether the control will wait for a true dial tone before dialing, or if it will
wait for a predetermined delay before dialing (delay is programmed in Dial Tone Pause
field *42). The latter may be necessary in high-noise environment telco networks where
noise can be confused with dial tone, resulting in premature dialing.
Enter 1 for true dial tone wait. If no dial tone is detected, will dial at end of pause
programmed in field *42.
Enter 0 to pause for seconds entered in field *42, then dial.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...