Section 22 – Data Field Descriptions
22-7
*52
STANDARD/EXPANDED REPORT PRIMARY
Alm
Rst
Byp
Trbl
Opn/Cls
Low Batt
Enter 0 for standard or 1 for expanded reporting for the primary phone number; default
is 0.
Note: Expanded overrides 4+2 format.
*53
STANDARD/EXPANDED REPORT SECONDARY
Alm
Rst
Byp
Trbl
Opn/Cls
Low Batt
Enter 0 for standard or 1 for expanded reporting for the secondary phone number;
default is 0.
Note: Expanded overrides 4+2 format.
*56
DYNAMIC SIGNALING DELAY
[00]
Select the time the panel should wait for acknowledgment from the first reporting
destination before it attempts to send a message to the second destination (first and
second destinations are determined in field
✳
57). If the acknowledgment is received
before the delay time expires, no message is sent to the second destination.
Enter the delay time (00-15) times 15 seconds.
*57
DYNAMIC SIGNALING PRIORITY
[0]
Select the initial reporting destination for central station messages.
0 = Primary Dialer; 1 = Long Range Radio
*58
LONG RANGE RADIO CENTRAL STATION #1 CATEGORY ENABLE
Alm
Trbl
Byp
Opn/Cls Syst
Test
Enter 1 to enable reports for primary Subscriber ID of Long Range Radio. Otherwise,
enter 0. Default = 0.
*59
LONG RANGE RADIO CENTRAL STATION #2 CATEGORY ENABLE
Alm
Trbl
Byp
Opn/Cls Syst
Test
Enter 1 to enable reports for secondary Subscriber ID of Long Range Radio. Otherwise,
enter 0. Default = 0.
*64
ALPHA NUMERIC PAGER INSTALLED
[0]
Enter 1 if the alpha numeric pager interface is installed. Otherwise enter 0.
*65
PAGER PHONE NUMBER FOR ALARMS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This field is used to enter the alpha numeric paging service phone number for Alarm
reports. Enter up to 17 digits, 0-9; enter #11 for *, #12 for #, and #13 for a 2-sec.
pause. Do not fill unused spaces. Enter * after the last digit of the phone number.
*66
PAGER ID NUMBER FOR ALARMS
This field is used to enter the Pager ID number for Alarm reports. Enter up to 10 digits.
If fewer than 10 digits are required, enter * after the last digit, (i.e., pager pin number).
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...