Section 22 – Data Field Descriptions
22-9
*76
PAGER ID NUMBER FOR TEST
This field is used to enter the Pager ID number for Test reports. Enter up to 10 digits.
If fewer than 10 digits are required, enter * after the last digit, (i.e., pager pin number).
*79
ZONE TYPE RESTORES FOR ZONE TYPES 1-8
1 2 3 4 5 6 7 8
Enter 1 to enable Restore reporting for individual zone types.
Enter 0 if no Restore report is desired for a zone type. Default = 0.
*80
ZONE TYPE RESTORES FOR TYPES 9/10
9
10
Enter 1 to enable Restore reporting for individual zone types.
Enter 0 if no Restore report is desired for a zone type. Default = 0.
*83
FIRST TEST REPORT TIME [00, 12, 00]
|
|
|
Enter the day (00-07) and time (00-23 hours/00-59 min.) that the first Test report shall
be transmitted.
Enter 00 in all locations if the Test report is to be sent immediately upon exiting.
Enter 00 in the day location if the report is to be sent at the next occurrence of the time
that is set.
Note: that day 01=Monday. See Report Code Programming (System Group 1) in the #93
Menu Mode Programming section for assigning the Test Report Code.
*84
SWINGER SUPPRESSION (partition-specific)
[03]
|
This option limits the number of messages (alarms or troubles) sent for a specific
channel in an armed period (Swinger Suppression). Enter 01-15. If 00 is selected, all
alarm or trouble codes are reported.
Must be 00 (disabled) for UL installations.
*85
ENABLE DIALER REPORTS FOR PANICS & DURESS
[1111]
(partition-specific)
95
96
99
Duress
Enter 1 for each panic/duress for which reporting is desired.
Note: Non-zero report code must be assigned to zone 992 (duress) to enable Duress
reporting.
*87
ENTRY WARNING (partition-specific)
[1]
Enter 0 for 3 short beeps, or 1 for slow beeps that continue for the entire entry delay
period.
*88
BURG. ALARM COMM. DELAY (partition-specific)
[0]
Enter 0 for no delay on burglary alarm communication. Enter 1 for 16-second delay (no
delay on 24-hour reports). Must be 0 for UL installations.
*89
RESTORE REPORT TIMING
[0]
Enter 0 for instant Restore report as zone restores.
Enter 1 for reporting after bell timeout if zone restored. Enter 2 for Restore report
when system is subsequently disarmed. Must be 2 for UL commercial burglary
installation.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...