Section 1 – General Description
1-3
User Codes
Accommodates 150 user codes, all of which can operate any or all partitions. Certain
characteristics must be assigned to each user code, which are as follows:
•
Authority level (Master, Manager, or several other Operator levels)
•
Opening/Closing central station reporting option
•
What partitions the code can operate
•
Global arming capability (ability to arm all partitions the code has access to in one
command)
•
Use of an RF (button) to arm and disarm the system (RF key must first be enrolled into
the system)
Peripheral Devices
Supports up to 31 addressable devices, which can be any combination of keypads (6139), RF
receivers (5881), relay modules (4204/4204CF), and 4285/4286 VIP module. Peripheral
devices have the following characteristics:
•
Each device set to an individual address (physically) according to the device's
instructions
•
Each device enabled in the system using Device Programming (covered later in this
manual)
At least one 2-line alpha keypad (6139) must be connected to the system for programming (if
using keypad programming) and must remain connected to the system in order to allow the
primary user to program additional user codes into the system at a later time.
Keypad Panic Keys
Accommodates three keypad panic keys: 1 +
✴
(A),
✴
+ # (B), and 3 + # (C).
•
Designated as zones 995 (1 +
✴
), 996 (3 + #), and 999 (
✴
+ #)
•
Activated by wired and wireless keypads
•
Activated and reported separately by partition, distinguished by subscriber account
number (or partition number if Contact ID reporting is used)
Keypad Macros
Accommodates 32 keypad macro commands per system (each macro is a series of keypad
commands). For example, by pressing either the A, B, C, or D key, the system can be
programmed to log onto another partition, bypass Zones 2 and 3, and arm that partition in
the AWAY mode (explained in detail later in this manual). Characteristics of keypad macros
are:
•
Assignable to the A, B, and C keys by partition
•
Other macros, (not assigned to these keys) executed by using the D key
•
Each macro can be 32 characters (keystrokes) in length
Optional Output Devices
Accommodates the use of 96 outputs using ADEMCO's 4204 and 4204CF Relay Modules, Fire
System Annunciators (FSA-8, FSA-24), V-Plex Relay Modules and Powerline Carrier Devices
(X-10). Each 4204 module provides four Form C relays for general purpose use. Each
4204CF provides two style-Y supervised bell outputs. The FSA-8 provides 8 LED outputs
and the FSA-24 provides 24 LED outputs.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...