Section 22 – Data Field Descriptions
22-13
1*44 WIRELESS KEYPAD TAMPER DETECT
[0]
Enter 1 to enable tamper detection on wireless keypad.
Enter 0 if tamper detection is not desired. If this feature is enabled, any attempt to
tamper by means of many trial entries at a wireless keypad will be blocked by the
control panel. If more than 40 key depressions are received without a valid sequence
(arm, disarm, etc.), the Control panel will disable the wireless keypad. The inhibit is
removed once a valid key sequence is received from a wired keypad.
1*45 EXIT DELAY SOUNDING (partition-specific)
[0]
Enter 1 if beeping from the keypads during exit delay are desired. Enter 0 for no
keypad sound during exit delay.
1*46 AUXILIARY OUTPUT MODE
[0]
Enter 0 if ground start output is required.
Enter 1 if the auxiliary output will be used to produce an open/close trigger (produced
only if ALL partitions are armed).
Enter 2 if the auxiliary output will be used to produce keypad-like sounding at an
auxiliary sounder (ex. 706-12). This option applies only to the partition enabled in field
*15.
Enter 3 if AAV module is being used.
NOTE: Only one of the above options may be active within the system.
1*47 CHIME ON EXTERNAL SIREN (partition-specific)
[0]
Enter 1 for chime annunciation using the external alarm sounder. If not desired, enter
0.
1*48 WIRELESS KEYPAD ASSIGNMENT
[0]
Enter the partition in which RF keypad is used, 1-8.
Enter 0 if no RF keypad is used.
1*49 SUPPRESS TX SUPERVISION SOUND
[1]
Enter 1 to disable trouble sounding for transmitter check-in failure.
Enter 0 if audible trouble sounding is desired.
Must be 0 for UL.
1*52 SEND CANCEL IF ALARM + OFF (partition-specific)
[0]
Enter 1 if Cancel reports are to be sent when the system is disarmed after an alarm,
regardless of how much time has gone by.
Enter 0 if Cancel reports are to be sent within Bell Timeout period only.
1*53 DISABLE DOWNLOAD CALLBACK
[0]
Enter 1 to disable the callback requirement for downloading.
Enter 0 to require a callback.
Must be 0 for UL commercial burglary installations.
1*56 AC 60Hz or 50Hz
[0]
Enter 1 for 50 Hz Standard or 0 for 60 Hz Standard. Must be set to 0 for U.S.
installations (this is the default).
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...