Section 22 – Data Field Descriptions
22-15
1*76 ACCESS RELAY # # (partition-specific)
[00]
|
The system can be programmed to provide user-activated access control. If enabled, the
assigned relay will pulse for 2 seconds when the user enters his code and presses 0.
Enter the relay number (00-96) for the relay that will be used for access control. Enter
00 if not used in this partition. This function has not been UL Listed for use with the
VISTA-50PEN control. Must be 00 for UL installations.
*Note: See the Access Control section for enhanced access control capability.
2*00 NUMBER OF PARTITIONS
[1]
Enter the number of partitions (1-8) to be used in the system.
2*01 DAYLIGHT SAVING TIME START/END MONTH
[04,10]
|
|
Enter the months (00-12) in which daylight savings time starts and ends.
Enter 00, 00 if daylight savings time does not apply to the user's region. Standard
setting for U.S. is 04,10.
2*02 DAYLIGHT SAVING TIME START/END WEEKEND
[1,5]
Enter the start and end weekends for daylight savings time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting
for U.S. is 1,5.
UL
Fields 2*05 – 2*08 must be set to 0 for UL installations.
2*05 AUTO-ARM DELAY (partition-specific)
[15]
|
Enter the time between the end of the arming window and the start of auto arm
warning time in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto arming is not desired.
2*06 AUTO-ARM WARNING PERIOD (partition-specific)
[15]
|
Enter the time 01-15 in one-minute increments during which the user is warned by a
keypad sounding and display to exit the premises prior to auto arming of the system.
Enter 00 to disable the warning period.
2*07 AUTO-DISARM DELAY (partition-specific)
[15]
|
Enter the time between the end of the disarming window and the start of auto
disarming of the system in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto disarming is not desired.
2*08 FORCE ARM ENABLE (FOR AUTO-ARM) (partition-specific)
[0]
Enter 1 if the system should automatically bypass any faulted zones when it attempts to
auto arm. Otherwise enter 0.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...