VISTA-50PEN Installation and Setup Guide
22-16
2*09 OPEN/CLOSE REPORTS BY EXCEPTION (partition-specific)
[0]
Enter 1 if Open/Close reports are to be sent only if the openings/closings occur outside
the arm and disarm windows. Open reports will also be suppressed during the closing
window in order to prevent false alarms if the user arms the system, then reenters the
premises to retrieve a forgotten item. Note that openings and closings are still recorded
in the event log. Enter 0 if exception reporting is not desired. Note: This field must be
set to 1 if No Opening and No Closing reports are to be sent.
2*10 ALLOW DISARMING ONLY DURING ARM/DISARM WINDOWS
(partition-specific)
[0]
Enter 1 if disarming of the system should be allowed only during the arming/disarming
windows, or if the system is in alarm (if 2*11 is set to 1). Note that this applies only to
operator level users. Installer, Master and Manager level users can disarm the system
at any time. Enter 0 if disarming can occur at any time.
0=disable for displayed partition; 1=enable for displayed partition
2*11 ALLOW DISARM OUTSIDE WINDOW IF ALARM OCCURS
[0]
Used only if field 2*10 (partition-specific field) is set to 1.
Enter 1 to allow the system to be disarmed outside the programmed disarm (opening)
window if an alarm has occurred.
Enter 0 to allow disarming only during the disarm window, regardless of system status.
If field 2*10 is set to 0 for a partition, this field (2*11) has no effect for that partition.
2*18 ENABLE GOTO FOR THIS PARTITION (partition-specific)
[0]
Enter 1 if this partition is to be accessed from another partition's keypad using the
GOTO command. Otherwise enter 0.
2*19 USE PARTITION DESCRIPTOR
[0]
Enter 1 if partition descriptors will be programmed. If enabled, the normal keypad
display will include a partition number and four-digit descriptor).
Enter 0 to cause the keypads to display a nonpartitioned system type of display (no
partition number will appear).
2*20 ENABLE J7 TRIGGERS FOR PARTITION (partition-specific)
[1]
2*21 SUPERVISION PULSES FOR LRR
[000]
| |
F B S
Used for supervised connection to 7920SE.
Enter 1 to enable pulses for each type of LRR trigger (Fire, Burglary/Audible Panic,
Silent Panic/Duress. This option causes the control to send periodic short pulses on the
J7 radio triggers. These pulses are used by the 7920SE to determine that its connection
to the control is still intact.
Enter 0 if not desired.
Must be 1 for UL commercial burglary installations.
2*22 DISPLAY FIRE ALARMS OF OTHER PARTITIONS (partition-specific)
[0]
Enter 1 to allow fire alarms that occur on other partitions to be displayed at this
partition's keypad(s). Otherwise, enter 0.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...