VISTA-50PEN Installation and Setup Guide
24-2
Auto-Arm Delay
•
Auto-arm delay provides a delay (grace period) before auto arming.
•
It starts at the end of the closing time window.
•
The delay is set in 4-minute increments, up to 56 minutes in partition-specific program
field 2*05.
•
At the expiration of this delay, the auto-arm warning will start.
Auto-Arm Warning
•
The auto-arm warning causes the keypad sounder to warn the user of an impending
auto-arm.
•
The warning can be set from 1 to 15 minutes prior to the arming in partition-specific
program field 2*06.
•
During this period the keypad beeps every 15 seconds and displays "AUTO ARM
ALERT.” During the last 60 seconds, the keypads begin to beep every 5 seconds.
•
The panel arms at the conclusion of the auto-arm warning period.
Extend Closing Window
•
A user can manually delay the arm (closing) time window by 1 or 2 hours.
•
This is done by entering a keypad command ([User Code} + #82), which then prompts the
user to enter the desired extension time of 1 or 2.
•
This feature is useful if a user must stay on the premises later than usual.
•
The auto-arm delay and warning periods will begin at the end of the extension.
Force Arm
•
The force arm option causes the panel to attempt to bypass any faulted zones prior to
auto-arming (panel will perform a force-arm).
•
This option is set in partition-specific program field 2*08.
Auto Disarming
•
The system can automatically disarm a partition at the end of a pre-determined opening
(disarm) time window.
•
The disarming time can be delayed by using the auto-disarm delay feature.
Disarm Delay
•
Auto-disarm delay provides a delay before auto disarming. This delay is added to the end
of the disarm time window.
•
The delay is set in 4-minute increments, up to 56 minutes, in partition-specific program
field 2*07.
Restrict Disarming
•
This option allows disarming by users only during the disarm time window and during
the arming time window (in case user needs to re-enter premises after manually arming
the partition).
•
This option is set in partition-specific field 2*10.
•
If field 2*10 is set, it is highly recommended to set field 2*11 as well. This field allows
the partition to be disarmed outside the arm/disarm time windows only if the partition is
in alarm.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...