Section 1 – General Description
1-5
Event Log
Keeps a log of different event types (enabled in programming). The event log has the
following characteristics:
•
Stores up to 512 events
•
Can be viewed at the keypad or through the use of Compass software
•
Can be printed on a serial printer using a 4100SM Module including zone alpha
descriptors
•
Can store PassPoint events
•
Printed events can be sent to an alpha numeric pager
Scheduling
Provides the following scheduling capabilities:
•
Open/close schedules (for control of arming/disarming and reporting)
•
Holiday schedules (allows different time windows for open/close schedules)
•
Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and
disarming, etc.)
•
Access schedules (for limiting system access to users by time)
•
End User Output Programming Mode (provides 20 timers for relay control)
Communication Formats
Supports the following formats for the primary and secondary central station receivers:
•
ADEMCO Low Speed (Standard or Expanded)
•
Sescoa/Radionics
•
ADEMCO Express
•
ADEMCO High Speed
•
ADEMCO Contact ID
•
Long Range Radio interface (ECP)
Audio Alarm Verification Option
Provides a programmable Audio Alarm Verification (AAV) option which can be used in
conjunction with an output relay to permit voice dialog between an operator at the central
station and a person at the premises. An optional AAV unit, such as Eagle model 1250, is
required.
UL
The Eagle Model 1250 AAV unit is not UL Listed
.
Cross-Zoning Capability
Helps prevent false alarms by preventing a zone from going into alarm unless its cross-zone
is also faulted within 5 minutes.
Exit Error False Alarm Prevention Feature
•
System can tell the difference between a regular alarm and an alarm caused by leaving
an entry/exit door open. If not subsequently disarmed, faulted E/E zone(s) and/or interior
zones will be bypassed and the system will arm.
•
Generates an Exit Error report by user and by zone to the central station.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...