VISTA-50PEN Installation and Setup Guide
24-10
Holiday Schedules
A holiday schedule will override the regular daily open/close schedule on the programmed
holidays throughout the year.
Holiday Schedule Worksheet
The system provides up to 16 holidays that can be assigned for the system. Each holiday can
be assigned to any combination of partitions. List the desired holidays in a Month/Day format
on the worksheet. Check the partitions for which these holidays apply.
HOL
Partition
Month/Day
1
2
3
4
5
6
7
8
1
/
2
/
3…16
/
Holiday Schedule Programming
After entering Scheduling Menu Mode, press 0 until the “Holidays ?” prompt appears.
Holidays ?
1 Yes 0 = No 0
Enter 1 to program holiday schedules.
HOLIDAY NUMBER ?
01-16, 00=Quit 01
Enter the 2-digit holiday number (01-16) to be programmed
and press [
∗
] to accept entry.
Enter 00 + [
∗
] at the “Holiday Number?” prompt to quit the
holiday menus and display the “Quit ?” prompt.
01 ENTER DATE
00/00
The cursor will be positioned on the tens of months digit. Enter
the appropriate month, then press [
∗
] to proceed to the day
field.
Enter the appropriate day for the holiday.
Press [
∗
] to accept the entry.
Part ? 12345678
Hit 0-8 x x
Holidays can be set for any partition, as follows. Press 0 to
turn all partitions on or off, or use keys 1-8 to toggle the letter
“x” under the partition to which this holiday will apply.
Press the [
∗
] key when all desired partitions have been
assigned.
The “Holiday Number?” prompt will be displayed again.
Repeat the procedure for each holiday to be programmed.
Quit ?
1 = YES 0 = NO 0
Enter 0 at the “Quit ?” prompt to return to the main menu
choices and continue programming.
Enter 1 to quit Scheduling Menu Mode.
Time-Driven Events
These are the schedules used to activate outputs, bypass zones, etc. based on a time schedule.
There are 20 of these events that may be programmed for the system, with each event
governed by the previously defined time windows.
The actions that can be programmed to automatically activate at set times are: relay
commands, arm/disarm commands, zone bypassing commands, and open/close access
conditions.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...