Section 24 – Scheduling Options
24-13
Additional Commands
Action Code
Action Specifier
75 Run Macro
Macro #
76 Run Script
Script #
77 Access Point Group Enable
Group #
78 Access Point Group Disable
Group #
3) Enter the desired activation time, which refers to when the action is to take place
relative to the time window. Select from:
Activation Time
Description
1
Beginning of time window
2
End of time window
3
During time window active period only (On at beginning of
window, off at end). This can be used in conjunction with the
arm, disarm or bypass commands to control a part of the
system during the window.
For example, if bypass is selected to activate during the
window, the zones in the zone list will be bypassed at the
beginning of the window and unbypassed at the end of the
window.
4
Beginning and end of time window (e.g., -a Coffee break
buzzer). In this example, if relay pulse is selected, the relay will
pulse for 2 seconds at the beginning of the window, signaling
the beginning of the coffee break. At the end of the window it
will pulse again, signaling the end of coffee break.
Automatic Refresh Feature
The system automatically updates the status of all Time-Driven Events upon any of the
following occurrences:
•
Changing of the time or date via #63 mode
•
Exiting #80 Scheduling Menu mode
•
Exiting Program mode
•
After a disconnect from the downloader
•
On a power-up
•
At Daylight Saving Time adjustment.
Time-Driven Event Programming
The following schedules can be used to activate outputs, bypass zones, arm/disarm the
system, etc. based on a time schedule. Up to 20 events can be programmed for the system.
Time windows must first be defined in order to be used to trigger events.
If using time-driven events to control relays, the following menu items must first
be programmed using Output Programming in the #93 Menu Mode:
Enter Relay No.
(reference identification number)
Output Group
(if applicable)
Restriction
Output Type
(4101SN, 4204, X-10, or FSA)
ECP Address
Relay No.
if 4204 relays
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...