Section 29 - Keypad Functions
29-3
Access Control
The system has the capability to utilize access control by one of 4 methods.
1.
One relay may be used for access control in each partition. The relay is programmed in
data field 1*76. To activate this relay, the user enters his User Code + [0]. The relay will
pulse for 2 seconds.
2.
For a more powerful method of access control, program input devices (keypads, RF
buttons, hardwired) and access points (using VistaKey or PassPoint ACS) (see the Access
Control section). Up to 32 access point devices (relays) among 8 partitions can be
controlled. For example, if a keypad is programmed as an access input device, then
entering [User Code] + [#73] or [User Code] + [#74] will activate the appropriate
access point relays (see also Zone Programming and Output Programming in the #93
Menu Mode section of the Programming Guide).
3.
If a Vista Gateway Module along with the ADEMCO PassPoint Access Control System or
a VistaKey module is installed, then these same inputs will automatically control the
appropriate access points. Entering [User Code] + [#75] will control the state (protect,
bypass, grant) of a door. (see the Access Control section).
4.
If a VistaKey module is installed, entering [User Code] + [#77] enables the user to
instantly perform an access control function. See the VistaKey-SK Installation and Setup
Guide for a detailed explanation of these functions.
Delaying Closing Time
If open/close schedules are used, end users can manually delay closing time by extending the
closing window by 1 or 2 hours. This is useful if a user must stay on the premises later than
usual. The user must have an authority level of Manager or higher.
To extend the closing window, enter [User code] + [#] +82.
Closing Delay ?
Hit 0-2 Hours
Enter the number hours, 1 or 2, by which the end of the closing
window should be extended. Note that the delay is from the
scheduled closing time, not from the current time.
Press [
∗
] to accept entry and exit this mode. Press [#] to exit this
mode without changes.
The system will send an Access Schedule Change report to the
central station when the closing window is extended (if
programmed).
An extension of the closing window cannot be reduced once it is set. However, a 1-hour delay can
be increased to 2 hours. This is to prevent the user from deleting the delay after the normal window
expires, thereby missing the end of the window.
Partition "GOTO" Commands
Each keypad is assigned a default partition for display purposes, and will show only that
partition's information. To see information for another partition, or perform system functions
in another partition, use the GOTO command ([User Code] + [*] +partition number 0-8).
The keypad will remain in the new partition until directed to go to another partition, or until
120 seconds has elapsed with no keypad activity. To return to your home partition, enter [
∗
]
+ Partition number 0.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...