S E C T I O N 3 0
Testing The System
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Battery Test
♦
Dialer Test
♦
Burglary Walk Test
♦
Armed Burglary System Test
♦
Testing Wireless Zones
♦
Trouble Conditions
♦
Turning the System Over to the User
♦
To The Installer
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Battery Test
When AC power is present, the VISTA-50PEN runs a brief battery test every 60 seconds to
determine if the battery connected, and runs an extended battery test every 4 hours to check
the battery’s condition. If the VISTA-50PEN finds the battery voltage is low (less than
approximately 11.5V) during one of these tests, it displays “SYSTEM LOBAT” on the keypad
and a rapid Keypad beeping sound. It also sends a Low Battery report to the central station
(if programmed). Clear the keypad by entering any security code + OFF. A Restore report is
sent to the central station after a subsequent test indicates the problem has been corrected.
Dialer Test
The VISTA-50PEN may be programmed to automatically transmit test reports to a central
station at intervals ranging from once per hour to once per 999 hours (field *27). UL requires
that a test report be transmitted at least once every 24 hours. The VISTA-50PEN can be
programmed to send the first report at any time of the day, or on any day of the week after
power-up (field *83).
Burglary Walk-Test (Code + TEST [5])
This test causes the system to sound keypad beeps in response to faults on zones for the
purpose of allowing proper zone operation to be checked without triggering alarms. This test
can only be activated by the installer, a master user or manager user by entering the
corresponding security code and pressing TEST while the burglary portion of the system is
disarmed. UL requires that this test be conducted on a weekly basis.
When this test is first activated, the system will sound burglary bells (or any bell having a
non-zero response type in each bell's supervisory zone) for 3 seconds. The system will send a
Start of Walk-Test message to the central station. The keypads will display “Burg Walk Test
in Progress” and will sound a single beep every 15 seconds while the test remains active.
Open and close each protected door and window in turn. Each action should produce 3 beeps
from the keypad. Walk in front of any motion detectors. Listen for three beeps when the
detector senses movement. The keypad will display the zone number and alpha descriptor
while a door or window remains open or while a detector remains activated. The system
automatically issues a Zone 8 Glassbreak Detector Power Reset about 10 seconds after it
finds a fault on this zone, to allow faulted detectors to be reset.
To end this test, enter any security code and press OFF. An End of Walk-Test message will
be sent to the central station.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...