VISTA-50PEN Installation and Setup Guide
A-2
For Grade AA Service:
•
You must use a 7920SE Long Range Radio.
•
Connect the 7920SE to the VISTA-50PEN burglary/audible panic alarm trigger.
UL611/UL1610 Central Station Burglary Alarm
Follow the instructions for UL609 Local installations given above.
For Grade A Service:
•
You must use the VISTA-50PEN's dialer with a 7720 Long Range Radio.
•
Connect the control's burglary/audible panic alarm trigger (on J7 header) and the
659EN's phone line monitor output to the 7720. The 7720 will send a report to the
central station when a telephone line fault condition is detected.
•
Also connect the 7720's radio fault output to one of the VISTA-50PEN's EOLR-supervised
zones (i.e., 1-8). Program this zone for a trouble by day/alarm by night (type 05) or a 24-
hour alarm (type 07, 08) response to radio faults.
•
Program the control's dialer to send Burglary Alarm, Trouble, Opening/Closing,, and Low
Battery reports.
For Grade AA Service:
•
Follow the instructions for Grade A service, except use the 7920SE in place of the 7720.
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup
Requirements.
The California State Fire Marshal and UL have regulations which require that all residential
fire alarm control panels must be provided with backup battery which has sufficient capacity
to operate the panel and its attached peripherals devices for 24 hours in the intended
standby condition, followed by at least 4 minutes in the intended fire alarm signaling
condition.
The VISTA-50PEN can meet this requirement without using a supplemental power supply,
provided that the panel's outputs (including the current drawn from the auxiliary power
output terminals) are limited as shown below:
•
Output current is limited to 750mA maximum total auxiliary power, polling loop and bell
output current.
•
Maximum auxiliary current is 300mA (including polling loop current)
•
Use 14AH battery (Yuasa model NP7-12 recommended, use two connected in parallel. A
dual battery harness is provided with ADEMCO No. 4100EOLR Resistor kit (kit also
contains EOL resistors having spade lug/heat shrink tubing construction which has been
approved by UL and CSFM for fire zone usage). Both batteries will fit inside the panel's
cabinet.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...