VISTA-50PEN Installation and Setup Guide
4-4
AC Transformer and Battery
This product uses the 1361 transformer (1361CN in Canada). We recommend wiring all
zones and expansion modules according to each section's instructions before powering up the
system for programming and testing. Refer to the Final Power-Up Procedure section for
specific instructions on how to connect the transformer and backup battery.
If using Powerline Carrier devices, the 4300 transformer interface must be used instead of
the regular 1361 transformer. The 4300 supplies the control panel with AC, and also sends
control pulses through the premises electrical system to control the Powerline Carrier
devices. Refer to the Final Power Up Procedure for specific instructions on how to connect
the 4300 transformer.
Refer to the Final Power-Up Procedure section for battery standby calculations and battery
selection table.
Panel Earth Ground Connections
In order for the lightning transient protective devices in this product to be effective, the
designated earth ground terminal (terminal 30) must be terminated in a good earth ground.
Recommended wire gauge for the ground connection is #16 AWG run no further than 30 feet.
The following are examples of good earth grounds available at most installations:
•
Metal Cold Water Pipe: Use a non-corrosive metal strap (copper is recommended)
firmly secured to the pipe to which the ground lead is electrically connected and secured.
•
AC Power Outlet Ground: Available from 3-prong, 120VAC, power outlets only. To test
the integrity of the ground terminal, use a three-wire circuit tester with neon lamp
indicators, such as the UL-Listed Ideal Model 61-035, or equivalent, available at most
electrical supply stores.
The panel requires this connection in order for its lightning transient protection devices.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...