Section 10 – 4285/4286 VIP Module
10-3
To wire the VIP module, perform the following steps:
Step
Action
1
Make 12V (+) and (–) and data-in and data-out connections from the VIP Module
to the control, using the connector cable supplied with the VIP Module see figure
10-1. These are the same connections as for remote keypads.
2
Insert the keyed connector into the mating header on the VIP Module.
Connect terminals 1 through 7 on the VIP Module as shown in the table below.
4285/4286 Terminal
Connects to:
1. Phone In (Tip)
green wire of direct connect cord
2. Phone In (Ring)
red wire of direct connect cord
3. Phone Out (Tip)
brown wire of direct connect cord
4. Phone Out (Ring)
gray wire of direct connect cord
5. No Connection
6. Audio Out 1
∗
Speaker
7. Audio Out 1
∗
Speaker
∗
Supported by the 4286 only
3
YELLOW
NO CONNECTION
RED
BLACK
GREEN
TO CONTROL PANEL
KEYPAD CONNECTIONS
KEYED
HEADER
1
2345
6
7
NO
CONNECTION
4286 VIP MODULE
ANSWERING
MACHINE
PREMISES
ANSWERING
MACHINE AND
PHONES
TIP
RING
RJ31X
JACK
TIP
RING
INCOMING TELCO LINE
CALLER ID
UNIT
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE “HANDSET”
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
U.S. PATENT No. 4791658
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
GREY
BROWN
GREEN
RED
EARTH
GROUND
TIP RING TIP RING
4500
THERMOSTAT
GREEN
YELLOW
HANDSET INCOMING
TELCO LINE
NOTE:
4286 DEVICE
ADDRESS IS
FACTORY SET
TO “4”
SEE SPEAKER NOTE
SPEAKER NOTE: IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND CONNECT IN SERIES.
SPEAKER
VOLUME
CONTROL
LOUDER
Figure 10-1: 4285/4286 VIP Module Connections
Use an RJ31X Jack with the phone cable supplied with the control. Use an additional RJ31X
Jack and a direct-connect cord to make connections to the 4285/4286. Make all connections
exactly as shown in Figure 10-1. This is essential, even if the system is not connected to a
central station. The 4285/4286 will not function if this is not done. If the leads on the
cable are too short to reach their assigned terminals, splice additional wires to them, as
required.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...