Section 10 – 4285/4286 VIP Module
10-5
Step
Action
Connect keypad wiring as shown (see the chart below for the maximum wire run
length for wire gauge you are using).
NOTE: Run audio cable in separate 2-conductor twisted-pair cable (22AWG
recommended). This cable should be kept at least 6 inches from other types of
cables carrying potentially interfering signals, such as AC power, telephone, and
polling loop cables.
WIRE RUN LENGTHS
Wire Gauge
150mA
300mA
500mA
600mA
750mA
22 AWG
160ft
80ft
50ft
42ft
32ft
20 AWG
260mA
130mA
80mA
67mA
52mA
18 AWG
410mA
220mA
130mA
115mA
83mA
16 AWG
650mA
330mA
200mA
170mA
130mA
6
7
Set the keypad address, tamper option, and playback volume setting by pressing
and holding the [1] and [3] keys at the same time for 3 seconds, then follow the
prompts. You must press these keys within 60 seconds of power-up to set the
address and/or tamper option; you can set the volume at any time after power-up.
Refer to the instructions included with the keypad for additional details.
You must set TeleSmart keypads to addresses 0-7 only.
8
Control Panel Connections (see figure 10-5):
TeleSmart Plus is powered from the control’s +12VDC keypad terminal. Connect
the control’s keypad terminals to the TeleSmart Plus Control terminals as shown.
IMPORTANT: You must program the TeleSmart module as device address 08
when programming the control.
9
Real-Time Clock (RTC) Connection (optional) (see figure 10-6):
This connection is used to drive the TeleSmart internal clock. Connect either
terminal of the control’s AC input terminals to the TeleSmart RTC terminal.
10
Ground Connections (see figure 10-6):
Connect the TeleSmart ground terminal to a good earth ground.
TYPICAL
CONTROL’S
PHONE TERMINALS
LOCAL
INCOMING
INCOMING PHONE LINE
RING
TIP
RING
TIP
RING
TIP
RING
TIP
RING
TIP
RING
TIP
RED
RED
GREEN
GREEN
BROWN
BROWN
GRAY
GRAY
TO PREMISES PHONES
RJ31X
1
2
3
4
5
6
7
8
DIRECT
CONNECT
CORD
FROM
CONTROL
HOME
PHONES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
(CA38A in Canada)
Figure 10-2: TeleSmart Phone Connections
TROUBLESHOOTING NOTE:
If the system hangs up the phone line when
calling in from a remote location, check the
phone connection terminals:
Term. 17/18 = from control
Term. 15/16 = to house phones
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...