VISTA-50PEN Installation and Setup Guide
12-6
7920SE RADIO
FA
U
LT
ZONE 6
ZONE 3
ZONE 2
ZONE 1
EARTH GROUND
CABINET GROUND
SEE 7920SE INST. INSTR. FOR
INSTRUCTIONS ON POWERING UNIT
1 2
3
4
5
6
7
8
9 10
1 2
3
4
5
6
7
8
9 10
TB1
TB2
1 2
3
4
5
6
7
8
▲
▲
▲
GND (GRAY)
FIRE
(RED)
OPTIONAL
SILENT PANIC/DURESS
(BLACK) OPTIONAL
BURG/AUDIBLE PANIC
(BROWN) REQUIRED
28 29 30
J7
CONNECT TO
C-COM EARTH
GROUND SCREW
(TB30)
4142TR CABLE
▲
SEE NOTE 2
4.7K
(NOT SUPPLIED)
RADIO OK OUTPUT
(LOW ON FAULT)
659EN LINE FAULT MONITOR
FAULT
+12V GND
ORANGE
YELLOW
GREEN
PHONE LINE MONITOR
(+12V ON FAULT)
OPTIONAL
SEE NOTE 4
INCOMING PHONE LINE
PHONE LINE MONITOR
(OPENS ON FAULT)
REQUIRED
7 BLACK
6 RED
7920SE WIRING
NOTES:
FOR UL LISTED COMMERCIAL BURGLARY
INSTALLATIONS:
1. MOUNT THE 7920SE WITH 3 FEET OF THE
C-COM. RUN WIRING FROM C-COM TO
7920SE IN CONDUIT.
2. CONNECT RADIO OK OUTPUT TO C-COM
EOLR SUPERVISED ZONE (ZONE 2-7 ONLY).
USE 2K EOLR.
3. SEE UL INSTALLATION REQUIREMENTS ON A
LATER PAGE TO DETERMINE WHEN 659EN
USAGE IS REQUIRED.
4. CONNECT TO C-COM EOLR SUPERVISED
ZONE (ZONE 2-8 ONLY) WHEN DESIRED TO
HAVE PANEL LOCALLY ANNUNCIATE PHONE
LINE FAULTS.
EAR
TH GR
OUND
RING
TIP
}
}
TO C-COM AUX PWR
(35mA DRAW)
CONTROL
PANEL
Figure 12-6: Connections to 7920SELong Range Radios
7720 ULF RADIO
SEE 7720 ULF INSTRUCTIONS FOR
MORE DETAILED INSTALLATION
INFORMATION
FA
U
LT
4142TR
CABLE
FAULT
FAULT
ZONE 1
ZONE 2
ZONE 3
GR
OUND
RED FIRE ALARM
BROWN BURG / AUDIBLE PANIC ALARM
BLACK SILENT PANIC / DURESS ALARM
J7 CONNECTOR
NOTE 2: MOUNT THE 7720 WITHIN 3 FEET OF THE C-COM. RUN WIRING FROM C-COM TO 7720 IN CONDUIT.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- CUT RESISTOR JUMPERS Z1-Z3.
- DO NOT USE 2k EOL RESISTOR.
- PROGRAM 7720 ULF FOR SLAVE
OPERATION. PROGRAM ZONES 1-3
AS ALARM ZONES
J5
1
5
3
8
4
9
2
7
6
GRAY GROUND
GRAY
NOTE 1: CONNECT TO CONTROL PANEL'S HARDWIRE ZONES (2-8) USE 2K EOLR
RADIO FAULT
(PROGRAM FOR
SHORT ON FAULT)
SEE NOTE 1
7720ULF_1
Figure 12-7: Connections to 7720ULF Long Range Radio
Programming for Auxiliary Alarm Signaling Equipment
Program the following data fields:
*15
KEYSWITCH ENABLE: Make sure this field is set to 0. The keyswitch and the
auxiliary alarm signaling equipment cannot be used together.
1*46 AUXILIARY OUTPUT ENABLE: Set to "0" (factory default)
Event Log Printer
The VISTA-50PEN's event log can be printed on a local serial printer.
Connect a UL EDP Listed serial printer to the J8 connector using an ADEMCO 4100SM
Interface Module. Refer to Event Log Options section for wiring connections, printer
configuration, and a description of the keypad commands for event log printing.
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...