UL1023 Household Burglary Installations
For household burglary installations the total current drawn from the alarm output must not
exceed 1.7A. A battery must be installed since the combined auxiliary power, polling loop,
and alarm output, in excess of 750mA must be supplied by the battery.
Wire nonpolarized burglary indicating devices to the alarm output using a polarizing diode
as shown in Figure 15-2.
PANEL BELL
PANEL BELL
+
-
BELL
BELL
}
HORN
NON- POLARIZED BURGLARY
INDICATING DEVICES
POLARIZED FIRE
INDICATING DEVICE
TO OTHER
DEVICES
POLARIZING DIODES
(MUST MOUNT AT INDICATING DEVICE)
Figure 15-2: Wiring Nonpolarized Burglary Indicating Devices
Non-UL Installations
For non-UL installations, the total current drawn from this output can be up to 1.7 amps. A
battery must be installed since current in excess of 750mA is supplied by the battery. Up to
two 719 sirens can be used wired in parallel.
Programming the Alarm Output
Program the following data fields:
*13
Select Timeout for Bell
*16
Confirmation of Arming Ding for Bell
*21
PREVENT FIRE TIMEOUT (1=no timeout; 0=fire timeout
*23
MULTIPLE ALARMS (partition-specific)
1*47
Enable Chime for Bell
Summary of Contents for VISTA-50PEN
Page 2: ...ii...
Page 10: ...VISTA 50PEN Installation and Setup Guide x...
Page 26: ...VISTA 50PEN Installation and Setup Guide 3 4...
Page 42: ...VISTA 50PEN Installation and Setup Guide 6 6...
Page 56: ...VISTA 50PEN Installation and Setup Guide 8 8...
Page 82: ...VISTA 50PEN Installation and Setup Guide 13 4...
Page 110: ...VISTA 50PEN Installation and Setup Guide 18 8...
Page 118: ...VISTA 50PEN Installation and Setup Guide 20 4...
Page 138: ...VISTA 50PEN Installation and Setup Guide 22 18...
Page 166: ...VISTA 50PEN Installation and Setup Guide 25 6...
Page 172: ...VISTA 50PEN Installation and Setup Guide 27 2...
Page 186: ...VISTA 50PEN Installation and Setup Guide 29 8...
Page 192: ...VISTA 50PEN Installation and Setup Guide 30 6...
Page 197: ...B 1 A P P E N D I X B DIP Switch Tables...
Page 200: ...VISTA 50PEN Installation and Setup Guide B 4...
Page 214: ...l K3271 1BX 9 00 165 Eileen Way Syosset NY 11791 Copyright 2000 PITTWAY Corporation...