Chapter 4 - MotionBlox-40R
48
Adept Cobra s350 User’s Guide, Rev. A
Table 4-9. XIO Breakout Cable Wire Chart
Pin No.
Signal
Designation
Wire Color
Pin Locations
1
GND
White
26-pin male
connector on XIO
Breakout Cable
2
24 VDC
White/Black
3
Common 1
Red
4
Input 1.1
Red/Black
5
Input 2.1
Yellow
6
Input 3.1
Yellow/Black
7
Input 4.1
Green
8
Input 5.1
Green/Black
9
Input 6.1
Blue
10
GND
Blue/White
11
24 VDC
Brown
12
Common 2
Brown/White
13
Input 1.2
Orange
14
Input 2.2
Orange/Black
15
Input 3.2
Gray
16
Input 4.2
Gray/Black
17
Input 5.2
Violet
18
Input 6.2
Violet/White
19
Output 1
Pink
20
Output 2
Pink/Black
21
Output 3
Light Blue
22
Output 4
Light Blue/Black
23
Output 5
Light Green
24
Output 6
Light Green/Black
25
Output 7
White/Red
26
Output 8
White/Blue
Shell
Shield
Pin 9
Pin 1
Pin 1
8
Pin 10
Pin 19
Pin 26
Summary of Contents for Cobra s350
Page 1: ...Adept Cobra s350 Robot User s Guide...
Page 2: ......
Page 16: ...Chapter 1 Introduction 16 Adept Cobra s350 User s Guide Rev A...
Page 34: ...Chapter 3 Robot Installation 34 Adept Cobra s350 User s Guide Rev A...
Page 50: ...Chapter 4 MotionBlox 40R 50 Adept Cobra s350 User s Guide Rev A...
Page 62: ...Chapter 5 System Installation 62 Adept Cobra s350 User s Guide Rev A...
Page 66: ...Chapter 6 System Operation 66 Adept Cobra s350 User s Guide Rev A...
Page 84: ...Chapter 8 Maintenance 84 Adept Cobra s350 User s Guide Rev A...
Page 90: ...Chapter 9 Technical Specifications 90 Adept Cobra s350 User s Guide Rev A...
Page 98: ...Chapter 10 Cleanroom Robots 98 Adept Cobra s350 Robot User s Guide Rev A...
Page 102: ...Index 102 Adept Cobra s350 User s Guide Rev A...
Page 103: ......
Page 104: ...3011 Triad Drive Livermore CA 94551 925 245 3400 P N 05624 000 Rev A...