Cobra s600/s800 Internal Connections
Adept Cobra s600/s800 Robot User’s Guide, Rev H
113
8.2
Cobra s600/s800 Internal Connections
Figure 8-9. Adept Cobra s600/s800 Internal Connections Diagram
8.3
XSLV Connector
Table 8-1. XSLV Connector Pinout
Pin #
Description
Comment
Pin Location
1
ESTOPGND
ESTOP System Ground
XSLV1/2 Connector
as viewed on Cobra
2
MAN1
ESTOP Manual Input Ch 1
3
MAN2
ESTOP Manual Input Ch 2
4
HIPWRDIS
High Power Disable
5
ESTOP_RESET
Normally Closed Check Contacts
6
AUTO1
ESTOP Auto Input Ch 1
7
AUTO2
ESTOP Auto Input Ch 2
8
N/C
9
ESTOP_SRC
ESTOP 24 V
Mating Connector:
AMP/Tyco #747904-2, 9-pin D-Sub
AMP/Tyco #748676-1, D-Sub Cable Clamp
Co
b
ra s600/s800
Internal Connections
SmartController
Connections
Force-G
u
ided Relay
Cyclic Check
Control Circ
u
it
Force-G
u
ided
Force-G
u
ided
Sin
g
le-Phase
AC Inp
u
t
200-240VAC
Hi
g
h Power to
Amplifiers
Man 1
Man 2
A
u
to 1
A
u
to 2
XSLV-2
XSLV-3
XSLV-6
XSLV-7
ESTOPSRC
ESTOPGND
HPWRREQ
XSLV-9
XSLV-1
XSLV-5
To XSYS on
SmartController
Pin 1
Pin 5
Pin 6
Pin 9
Summary of Contents for Cobra s600
Page 1: ...Adept Cobra s600 s800 Robot User s Guide...
Page 2: ......
Page 14: ......
Page 20: ......
Page 52: ......
Page 68: ......
Page 80: ......
Page 116: ......
Page 132: ......
Page 146: ......
Page 151: ......
Page 152: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03017 000 Rev H...