Chapter 4 - System Installation
46
Adept Cobra s600/s800 Robot User’s Guide, Rev H
4.6
Connecting 200-240 VAC Power to Robot
Specifications for AC Power
NOTE:
The Adept robot system is intended to be installed as a piece of
equipment in a permanently-installed system.
WARNING:
Appropriately sized Branch Circuit Protection
and Lockout / Tagout Capability must be provided in
accordance with the National Electrical Code and any
local codes.
Ensure compliance with all local and national safety and
electrical codes for the installation and operation of the
robot system.
Table 4-5. Specifications for 200/240 VAC User-Supplied Power Supply
Auto-Ranging
Nominal
Voltage
Ranges
Minimum
Operating
Voltage
a
a
Specifications are established at nominal line voltage. Low line voltage can affect robot
performance.
Maximum
Operating
Voltage
Frequency/
Phasing
Recommended
External Circuit
Breaker,
User-Supplied
200 V to 240 V
180 V
264 V
50/60 Hz
1-phase
10 Amps
Table 4-6. Typical Robot Power Consumption
Cobra Robot
Move
Average
Power (W)
RMS
Current (A)
Peak Power
(W)
a
a
For short durations (100 ms)
s600/i600
No load - Adept cycle
b
b
344
1.56
1559
5.5 kg - Adept cycle
494
2.25
2061
5.5 kg - all joints move
880
4.00
2667
s800/i800
No load - Adept cycle
531
2.41
1955
5.5 kg - Adept cycle
377
1.71
1406
5.5 kg - all joints move
794
3.61
2110
Summary of Contents for Cobra s600
Page 1: ...Adept Cobra s600 s800 Robot User s Guide...
Page 2: ......
Page 14: ......
Page 20: ......
Page 52: ......
Page 68: ......
Page 80: ......
Page 116: ......
Page 132: ......
Page 146: ......
Page 151: ......
Page 152: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03017 000 Rev H...