Chapter 6 - Optional Equipment Installation
80
Adept Cobra s800 Inverted Robot User’s Guide, Rev C
Figure 6-10. Solenoid Placement Using Mounting Hardware
9. Install the appropriate lengths of 5/32 inch plastic tubing (supplied) into the two
output ports on the manifold.
10. Route the tubing up along the tower bracket next to the quill and down through
the center of the quill.
Use tie-wraps as needed to secure the tubing.
11. For the IP-65 version robot, skip to
.
12. Remove the four screws from the User Connector Panel (see
) and remove the cover enough so you have access to the tubing under the
cover. See
Figure 6-11. Connecting Spare Air Line to User Connector
Air intake
coupling with
spare air line
Tubing connected
to output port
Mounting screws for
solenoid assembly
User Air fitting for
connecting spare line.
Remove factory
installed tubing first.
User Connector Panel
cover lifted to access
spare air line