background image

 

 

 

wood floor 

 

 

 

 

 

 

 

 

 

 

 

· Remember to measure the resistance three times. 

· Only for indoor installation. Do not install Foil Heating Mat in walls or ceilings. 

· The minimum installation temperature is 

5

°C(

40

°F)

.

 

· The heating cable cannot be cut to length, crossed over itself, or installed too close. 

· Remember to check that the supply voltage matches the voltage of the Foil Heating Mat. 

· Remember to place the labels as written in this instruction. 

Please consult your supplier for any other questions or advice. 

 

3 Floor Heating Design and Product Selection 

3.1 Design the Installation 

Step 1: Measure the heated area 

Determine the heated area of the floor where there are no permanent fixtures or furniture such as 

showers, toilets, vanities, or cabinets. Measure the heated area of the floor. 

For example, in Figure 3, the area of the bathroom is 8.75 m

2

. When you subtract the area of the 

vanity, shower and toilet, the total heated area is only 6.45 m

2

Step 2: Determine the power supply voltage 

Make sure the supply voltage was 230 V. 

Step 3: Plan the design 

Determine the optimum floor heating mat layout for your heated area to ensure coverage. Select a 

spot for the thermostat in the wall above the heated area where it can be reached by the 2.5m cold 

lead on the Foil Heating Mat, and the 3.0m floor temperature sensor. Please refer to Figure 4. 

 

        Important 

The predetermined Foil Heating Mat spacing must be maintained to ensure proper floor heating. 

Do not change the Foil Heating Mat heating cable spacing when you lay out the cable or the floor 

may have cold spots. 

 

 

 

 

 

Insulation board 

Subfloor

 

 

Foil Heating Mat 

Summary of Contents for HM140/1

Page 1: ...I Foil Heating Mat System Installation Manual Floor heating System...

Page 2: ...ystem 2 2 1 Foil Heating Mat Specifications 2 2 2 Foil Heating Mat typical installations and applications 2 3 Floor Heating Design and Product Selection 3 3 1 Design the Installation 3 3 2 Confirm You...

Page 3: ...l Information 1 1 Use of the Manual Installing Foil Heating Mat is very easy to do Foil Heating Mat Systems combine the highest comfort levels with maximum energy efficiency It s a proven technology t...

Page 4: ...and after installation of wood floor 1 4 Lifetime Warranty From the date of purchase Adept warrants that the Foil Heating Mat heating cable is free from defects in material design and workmanship The...

Page 5: ...showers toilets vanities or cabinets Measure the heated area of the floor For example in Figure 3 the area of the bathroom is 8 75 m2 When you subtract the area of the vanity shower and toilet the to...

Page 6: ...your Foil Heating Mat is no larger than the heated area Following the example from Figure 3 if the heated area is 6 45 m2 select the 6 0 m2 Foil Heating Mat system Figure 3 Heated area example Figure...

Page 7: ...0 96 9 0 5 18 20 59 1 1260 5 48 42 0 HM140 10 10 107 6 0 5 20 20 66 6 1400 6 09 37 8 HM140 12 12 129 2 0 5 24 20 78 8 1680 7 30 31 5 4 Installation Important Tools and materials required You will req...

Page 8: ...PS insulation board directly underneath the heating mat s install the boards in a brick pattern below and tape the edges to prevent movement of the underlay during installation Step 4 TRANSFER LAYOUT...

Page 9: ...e your Foil Heating Mat from the packaging box carry out a resistance test Use a digital ohm meter to measure the resistance of the Foil Heating Mat and compare it to Table Record the measured resista...

Page 10: ...stalling the flooring NEVER CUT THE HEATING CABLE Step 8 STICK THE CONNECTING TAPE In order to protect the mat from damage we need some necessary protective measures A roll of Aluminum tape and Alumin...

Page 11: ...king warmth should be noticeable on the surface of the heating mat within minutes You are now ready to lay the final floor finish Take care not to damage the heating mats Do not drive nails or screws...

Page 12: ...ng on the type of room and your personal preferences 5 Commissioning Important For the extended Lifetime warranty to apply you must perform these tests record the results on the warranty card and reta...

Page 13: ...ed to verify the sensor integrity 1 Set your multimeter to the 200K ohm range 2 Connect the multimeter leads to the red and green lead wires 3 Make sure the meter reads between 9 25K ohms If you get a...

Page 14: ...the Product Selection Table of this manual Refer to Thermostat Installation and Operation Manual Refer to Section 4 of this manual and the Thermostat Installation and Operation Manual Refer to Thermos...

Page 15: ...S ANY WARRANTY EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ADEPT NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON FIRM OR CORPORATION TO ASSUME FOR IT ANY OTHER LIABILITY...

Reviews: