Chapter 5 - System Operation
66
Adept Viper s650/s850 Robot with MB-60R User’s Guide, Rev D
Figure 5-3. Connecting Digital I/O to the System
Table 5-2. Default Digital I/O Signal Configuration, Single Robot System
Location
Type
Signal Range
Controller XDIO connector
Inputs
1001 - 1012
Outputs
0001 - 0008
sDIO Module 1
Inputs
1033 - 1064
Outputs
0033 - 0064
sDIO Module 2
Inputs
1065 - 1096
Outputs
0065 - 0096
sDIO Module 3
(recommended
a
)
Inputs
1201 - 1232
Outputs
0201 - 0232
sDIO Module 4
(recommended
Inputs
1233 - 1264
Outputs
0233 - 0264
IO Blox 1
Inputs
1113 - 1120
Outputs
0105 - 0112
SF
IEEE-1394
X2
SC-DIO
LINK
*S/N 3563-XXXXX*
X1
24V
0.5A
R
OK
X4
- + - +
1.1
1.2
XDC1 XDC2
X3
R
ON
SmartServo
IEEE-1394
1 2 3 4
SF
ES
HD
SW1
1.1
1.2
2.1
2.2
OK
1
2
3
XDIO
LAN
HPE
OFF
XSYS
CAMERA
Eth 10/100
XUSR
Device Net
XFP
RS-232/TERM
RS-232-1
XMCP
BELT ENCODER
SmartController CX
-+
-+
RS-422/485
XDC1 XDC2
24V
5A
*S/N 3562-XXXXX*
RS-232-2
Optional
sDIO #1
SmartController
MB-60R
Optional
IO Blox Device
XIO Connector
12 Input signals: 1097 to 1108
8 Output signals: 0097 to 0104
XDIO Connector
12 Input signals: 1001 to 1012
8 Output signals: 0001 to 0008
IO Blox #1
8 Input signals: 1113 to 1120
8 Output signals: 0105 to 0112
sDIO #1
32 Input signals: 1033 to 1064
32 Output signals: 0033 to 0064