Robot Flange Dimensions
Adept Viper s650/s850 Robot with MB-60R User’s Guide, Rev D
81
7.2
Robot Flange Dimensions
Figure 7-5. Robot Flange Dimensions
7.3
XSLV Connector
Table 7-1. XSLV Connector Pinout
Pin #
Description
Comment
Pin Location
1
ESTOPGND
ESTOP System Ground
XSLV1/2 Connector
as viewed on MB-60R
2
MAN1
ESTOP Manual Input Ch 1
3
MAN2
ESTOP Manual Input Ch 2
4
HIPWRDIS
High Power Disable
5
ESTOP_RESET
Normally Closed Check Contacts
6
AUTO1
ESTOP Auto Input Ch 1
7
AUTO2
ESTOP Auto Input Ch 2
8
N/C
9
ESTOP_SRC
ESTOP 24 V
Mating Connector:
AMP/Tyco #747904-2, 9-pin D-Sub
AMP/Tyco #748676-1, D-Sub Cable Clamp
Ø40 H8
Ø20 H7
6 Deep
4X M5 x 0.08
8 Deep
(31.5 B.C.)
Ø5 H7
7 Deep
0
- 0.039
+ 0.021
0
+ 0.012
0
Pin 1
Pin 5
Pin 6
Pin 9