The ARF6513E receivers are fixed by the fixing lugs onto the top (antenna) and bottom (stuffing 
box) parts of the housing. Any operation (drilling…) performed on the housing makes it lose its 
IP65 tightness rating. 
Remove the two stainless steel screws (A and B) and take the bottom part off to access the power 
supply terminal blocks and contacts. 
 

Remove the screws from the
part with stuffing box (A)

(B)

 

 
 

 

Power supply 

 

Turn off the power supply, then wire the power supply to the screw terminals and  -. 

RX

DC voltage supply

Maximum 24 V

BAUD

+V

0V

CTS RTS RXD TXD

CTRL

 

Power supply  

7V < +V < 24V 

 
 

 

Display 

 
The ARF6513E receiver is equipped with a green LED, that is lit when decoding is valid.  
 

PRODUCT INSTALLATION

Summary of Contents for ARF18

Page 1: ...Receiver 7 Dimensions 7 Product references 7 ARF18 6513E User Guide ADEUNIS RF 283 RUE LOUIS NÉEL 38920 CROLLES FRANCE DESK 33 0 4 76 92 07 77 FAX 33 0 4 76 08 97 46 E MAIL ARF ADEUNIS RF COM ________________________________________________________________________________________ SA au capital de 345 000 euros SIRET 430 190 496 00017 RCS Grenoble NAF 322A ...

Page 2: ...EEC Safety conformity to the standard EN 60950 according to the requirements of Low Voltage Directive 73 23 EEC Radio conformity is proven by compliance to harmonised standard EN 300220 covering essential radio requirements of the RTTE directive Notes Conformity has been evaluated according to the procedure described in Annex III of the RTTE directive The use of the spectrum is harmonised by the f...

Page 3: ...umber There is no learning phase any frame transmitted by an ARF6141A 2 buttons ARF6142A 4 buttons or ARF6143A 8 buttons 24 channel remote control is decoded Applications autonomous control of tertiary or industrial equipment Order transmission safety is achieved by means of a proprietary rotating code V 24VDC SUPPLY 0V 1 3 5 6 2 4 6 8 A B C 1 3 2 4 or or 1 2 to ARF6513E receiver V 0V Serial link ...

Page 4: ...crews A and B and take the bottom part off to access the power supply terminal blocks and contacts Remove the screws from the part with stuffing box A B Power supply Turn off the power supply then wire the power supply to the screw terminals marked and RX DC voltage supply Maximum 24 V BAUD V 0V CTS RTS RXD TXD CTRL Power supply 7V V 24V Display The ARF6513E receiver is equipped with a green LED t...

Page 5: ...2 speed on the serial link Switch 1 Switch 2 Speed ON ON 1200 ON OFF 2400 OFF ON 4800 OFF OFF 9600 Switches 3 and 4 type of flow control on the serial link Switch 4 Switch 3 Speed ON ON Position prohibited ON OFF RTS CTS OFF ON Xon Xoff OFF OFF no control Wiring N SUB D 9 Signal Cable 6517YB colour Vcc Pink 5 GND Grey 8 CTS Green 7 RTS Brown 3 TXD White 2 RXD Yellow Dashed Signal are not used Data...

Page 6: ... RTS input In daughter board version an antenna has to be added to achieve correct communication between the products This antenna should be a wire with a length of wave i e about 17 cm This value is the length that will have to extend outside the housing if this housing is metallic This antenna can be remote located using a coaxial cable with its braid stripped over the last 17 centimetres 17 cm ...

Page 7: ...P65 housing 104 x 300 x 35 mm Distance between fixing points 4 holes diam 4 to 92 x 61 mm Product references ARF6513E Remote controller decoder ARF6523A 4 relays receiver daughter board ARF6523B 4 relays receiver in IP65 housing ARF6524A 2 relays receiver daughter board ARF6141A 2 button remote control ARF6142A 4 button remote control ARF6143A 8 button 24 channel remote control ARF03 Antenna kit f...