EN
WMBUS TEMP - Guide utilisateur / User guide version V2.0.0
47 of 77
FR
1.4. Technical Specifications
1.4.1 General characteristics
Parameters
Value
Supply voltage
Nominal 3.6V
Power supply
Removable battery version: SAFT LS14500
Maximal courant
90mA
Working temperature
-25°C / +70°C
Dimensions:
105 x 50 x 27mm
Weight
130g
Casing
IP 67
Radio standards
EN 300-220, EN 301-489, EN 60950
1.4.2 Autonomy
Operating conditions:
Sending periodicity
Autonomy
Product shelf life before use: Maximum 1 year.
Calculations performed at a temperature of 20°C
Without super-sampling factor in the period
140 frame/day
18 years
100 frame/day
>20 years
50 frame/day
>20 years
20 frame/day
>20 years
10 frame/day
>20 years
2 frame/day
>20 years
The above values are estimations based on certain conditions of use and environment. They do not represent a commitment on the part of
adeunis®.
1.4.3 Sensor characteristics
Caracteristics
Internal sensor - temperature range
-30°C .. +70°C
Internal sensor - Inertia by 10°C steps
90 minutes
External sensor - temperature range
-55°C..+155°C
External sensor - Inertia by 10°C steps
15 minutes
External sensor - Cable length
2 meters
Resolution
0,1°C
Precision
+/- 0,1°C