User Guide | COMFORT LwM2M | NB-IoT / LTE-Cat-M1
43
The following table lists the parameters to be configured on the product to define a blackout period.
Parameters
Description
Default Configuration
Main Functions Blackout Period
Period during which the product
does not emit any sensor values.
Disabled
Blackout Start Time
Start time of the blackout period.
10 PM
📱
To configure a blackout period via the NFC IoT Configurator application, go to the
"CONFIGURATION" menu => Select the "APPLICATION" section => Choose the "General"
subsection => Configure the "Blackout Period of the main functions" and "Blackout Start
Time" => Apply the new configuration to the product via NFC.
💻
Configuring a blackout period via an LwM2M server
URI
Object Name
Resource Name
Access Type
Unit
Description
/34450/0/3
COMFORT
Blackout start
time
R/W
Hour
Start time of the
blackout period.
Please note that
the time is in
UTC format.
/34450/0/4
COMFORT
Blackout
duration
R/W
Hour
0 = disabled
5.4 Factory Reset
The COMFORT product can be restored to its default settings using the NFC IoT Configurator
application.
📱
To restore factory settings via the NFC IoT Configurator application, go to the
secondary menu at the top of the "CONFIGURATION" menu => Select the action "Restore
Default Configuration" => Apply the new configuration to the product via NFC.