2.1.4 DEAD mode
The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes
up every 5 seconds to make the red LED flash twice.
The replacement of the battery (if the product is a replaceable battery version) followed by the application of the magnet takes the product out
of this mode to return it to the operating mode.
2.2. Application operation
2.2.1 Periodic transmission
The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
Product in standby
Send frame 0x46
Period
reached?
Yes
No
Detected
and valida-
ted pulse
?
Counting
of the impulse
Yes
No
The settings associated with this mode of operation are:
• Transmission period (register 301)
• Enabling and Configuring inputs (register 320)
• Debounce timer period (registers S322)
A complete list of the registers can be found in paragraph 3.4.
Eg:
Registre
Value encoding
Value
Result
S301
Decimal
6
Periodic mode with a period of 6x10min = 60 minutes
S320
Hexadecimal
0x39
Channel A :
• Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
• Activated
•
Gas meter
•
Tamper input disabled
S322
Hexadecimal
0x57
Debounce :
•
Channel A = 500ms
•
Channel B = 100ms