2.2.5 Transmitting a Daily Frame
The product transmits every 24 hours a daily frame (0x30) according to the following diagram:
Product in standby
Initialization of min
and max flow rates
Period of
24h reached
?
Yes
Send frame 0x30
Initialization of alarm
states
No
The transmission period of the daily frame is fixed (24 hours) and not configurable.
Register
Value encoding
Value
Result
S320
Hexadecimal
0x39
Channel A :
• Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
• Activated
•
Gas meter
•
Tamper input disabled
S332
Decimal
2
Scan period for A-channel tamper input is 2x10s = 20s
S333
Decimal
3
Tamper detection threshold for A-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)
S334
Decimal
2
Scan period for B-channel tamper input is 2x10s = 20s
S335
Decimal
3
Tamper detection threshold for B-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)