3.4. Description of the registers
On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration
has not been changed).
Commands such as Modification TTY<n>=<M> or ATR allow you to change the content of the registers: <n> repre-senting the number of
the register and <m> the value to be assigned. This latter is either a decimal value or a hexadecimal value consistent with the «encoding»
column of the tables below.
Exemples :
• ATS300=6 assigns the decimal value 6 in register 300
• ATS302=2 assigns the hexadecimal value 0x02 in register 302
It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.
IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in the para-
graphs that follow are reserved and must not be changed.
3.4.1 Function registers
The list of registers below allows you to change the behaviour of the product application.
Register
Size
(bytes)
Description
Coding
Details
300
N/A
Transmission period of the
Keep Alive frame
---
Ignored value, the period is set to 24 hours (not configurable)
in OPERATION mode and 5 minutes in TEST mode
301
2
Transmission period of data
sensors
Decimal
Default: 144
Min/max: 1 to 144
Unit:
x 10 min if S306=1
x 20s if S306=2
304
2
PIN code
Decimal
Default value : 0 (disabled)
Min/max : 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
IMPORTANT: The product does not have a mechanism
to unlock the PIN code if it is activated and the code
is
forgotten.
306
1
Global operation
Decimal
Default: 0
Allows the product to be switched into one of the following
modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
• 3: DEAD mode
307
2
Number of downling frame
per day
Decimal
Default: 0
Min/Max: 0 to 4
Unit: none
See detail paragraph 4.2