sigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.0
84
Page
of 99
FR
0
1
2
3 to 4
5 to 6
7 to 8
9 to 10
Code
Status
PAYLOAD
0x48
Cf Status
Frame index
Delta A20
Delta B20
Delta A21
Delta B21
0x48
0xA3
0x0B
0x00C3
0x00F1
0x0005
0x00B5
0
1
2
3 to 4
5 to 6
Code
Status
PAYLOAD
0x48
Cf Status
Frame index
Delta A22
Delta B22
0x48
0xA3
0x0C
0x0012
0x0020
4.1.10
Summary of the conditions of the transmission of the uplink frames
The table below summarizes the conditions of the transmission of the different uplink frames:
Code
Description
Sending conditions
0x10
Frames of information on the
product configuration
• Product start-up
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x01
• Periodically if the inputs are deactivated (period defined by register S301)
0x20
Frames of information on the
network configuration
• Product start-up
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x02
0x30
Keep Alive frame
24 hours elapse since the start-up of the product or since the last transmission of this frame
(5 minutes in TEST mode)
0x31
Reply frame to a register value
request in a downlink frame
• Reception of a downlink frame 0x40
0x46
Data Frame
• Start-up of the product (RUN mode).
• Exit from the configuration mode (AT commande)
• Transmission period reached (period defined by register S301)
0x47
Alarm frame
Exceeded flow threshold on one of the two channels (sending only if the exceeded flow
control is enabled by writing a non-zero value in the S326 or S327 registers).
0x48 (x4) Periodic frame with 1 hour-history
1 hour elapses since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.
0x48
(x13)
Periodic frame with 24 hours-
history
24 hours elapse since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.