background image

Precaution For Use 

1.

 

The display cases shall be used in proper environment with ambient temp.<25

℃,

relative humidity<60%,and natural air speed<0.2m/s,higher temperature and humidity 
will affect cabient

s running. 

2.

 

The leakage protection device must be installed and make sure to ground 
adequately.running voltage can be changed within AC 220V

±

10%

if the voltage is 

unstable,choose stabilizer with proper capacity. 

3.

 

Do not let cabinets close to heat source or under sunshine directly,around passages and 
vent shall be closed to avoid damaging air curtain and affecting refrigeration effect. 

4.

 

It

s a normal phenomena that when the cabinet is defrosting,the internal temperature 

will rise in a short time. 

5.

 

The needle type valve si used for system test and refrigerant filling-up,so do not open it 
except professional people to prevent refrigerant leakage. 

6.

 

Do not store inflammable,explosive,volatile fluid or gas. 

7.

 

The shelves can stand not more tan50kg/m2,or the shelf may be damaged. 

8.

 

Put goods in and out carefully,do not throw goods to avoid damaging cabinets. 

9.

 

Reserve a certain place when arranging the foods,do not put foods in air return,or it will 
affect air flow in cabinet and affect storeage effect and increase the energy 
comsumption. 

10.

 

Regularly change foods place according to the principle

first in,first out

 to avoid out 

of-reach foods overdue or deterioration. 

11.

 

Clean food scraps timely to avoid block defrosting defrosting drainage and lead to ice 
clagging. 

12.

 

Every foods has its shelf life,do not store it indefinitely. 

13.

 

On the sake of clean,tidy and undrying,the foods shall be provided with good package. 

14.

 

Plug-in case has large tonnage,users shall discharge water at times. 

15.

 

Open or close night curtain slowly,let it go till open or close it completely. 

16.

 

Have circuit inspection for temperature every 2 hours and record it. 

Not:The leakage peotection device must be tested once a mouth.Ask professional 

people to maintain the cabinet if it is not running normally,Before maintaining it,cut 

down the power source,also you must wear security suits and use special tools. 

                                                           

  

  Main Characteristics 

Summary of Contents for BL-Store Series

Page 1: ...BL Store Series Instruction Contents Brief Introduction 1 Precaution for use 3 Main Characteristics 4 Daily Cleaning 5 Installation instruction 6 Maintenance 7 ...

Page 2: ...the shelf may be damaged 8 Put goods in and out carefully do not throw goods to avoid damaging cabinets 9 Reserve a certain place when arranging the foods do not put foods in air return or it will affect air flow in cabinet and affect storeage effect and increase the energy comsumption 10 Regularly change foods place according to the principle first in first out to avoid out of reach foods overdue...

Page 3: ...mperature by setting temperature controller let professional people do it wrong setting will damage compressor Daily cleaning and maintenance The performance and lifespan of the equipment is directly related with the daily maintenance and cleaning The regular maintenance of the display case and its parts and components can lengthen their lifespan and reduce the cost for use and maintenance List fo...

Page 4: ...ry not finished do not run the cabinet or the ice scraps will block beehive net holes Plug in compressing rack Clean compressing rack completely especially for compressor or it will down cabinet refrigeranting speed decrease refrigeranting capacity and increase internal temp long time no cleaning will lead to compressor burned out Note do not let water on th fan motor or it will burned out Once 2 ...

Page 5: ...sonable 2 Clean water spout A Discharge the dirts and scraps into prepared water box Note Dirts only allowed to take out do not let them enter drainage or it will block drainage B Pour proper water to the cabinet if not flows smoothly it means the main water pipe blocked tell the local maintrnance company Note Do not use high pressure water to rinse the cabinet to avoid danger Installation 1 Disas...

Page 6: ...ts so do not use them 6 Check the adiabatic layer of the suction pipeline and repair its breakage to ensure pipeline adiabatic function 7 Make sure the load is appropriate avoid use large posts in it do not let goods block or occupy the air channel Put goods tidy and clean 8 If there has air flow with opposite direction compare with air curtain it will has unbenefit influence on cooling capacity a...

Page 7: ... with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recy...