background image

 

 

 

 
The Gas Griddle

 

Installation and Operation Instructions

 

 
 

Model:

 EGG-48S, EGG-36S,EGG-24S,EGG-16S

 

  Gas catering equipment (Type A) EN 203-1:2014 / BSEN 203-2-9:2005

 

 

IMPORTANT FOR FUTURE REFERENCE

 

Please complete this information and retain this manual for the life of the equipment. For Warranty 

Service and/or parts, this information is required. 
 
These instructions are only valid if the country code appears on the appliance. If the code does not 

appear on the appliance, refer to the technical instructions for adapting the appliance to the conditions 
for use in that country”. 

 
 
 

 

WARNING: 

For your safety, do not store or use gasoline or other flammable vapors or 

liquids in the vicinity of this or any other appliances. Keep the area free and clear of 

combustible. 

 

 
 

WARNING 

: 

Improper installation, adjustment, alteration, service or maintenance can 

cause property damage, injury, or death. Read the installation operating and maintenance 
instructions thoroughly before installing, or servicing this equipment. 

 

 
 
WARNING

Instructions must be posted in a prominent location. All safety precautions 

must be taken in the event the user smells gas. Safety information can be obtained from 
your local gas   supplier. 

 
 
 
 
 
 
 

 

 

V0.Rev0.00-17 

Summary of Contents for EGG-16S

Page 1: ...for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other app...

Page 2: ......

Page 3: ...sions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners...

Page 4: ...IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF...

Page 5: ...lure Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take s...

Page 6: ...r s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in acco...

Page 7: ...luded The Gas griddle Plate Four Feet Instruction Manual Flue baffle Product specification list Gas orifice dia Gas pres Total power EGG 48S EGG 36S EGG 24S EGG 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x...

Page 8: ...5 Dimensions EGG 48S EGG 36S EGG 24S EGG 16S...

Page 9: ...from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor...

Page 10: ...label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubin...

Page 11: ...gh the regulator Refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression f...

Page 12: ...space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compa...

Page 13: ...ed in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Install...

Page 14: ...ration practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This app...

Page 15: ...l knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will r...

Page 16: ...in burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control...

Page 17: ...riddle thoroughly with a dry cloth and polish with a soft dry cloth NOTE If the Griddle usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensur...

Page 18: ...s control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a Good quality stainless steel cleaner or stainless ste...

Page 19: ...rned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control...

Page 20: ...ntact you re nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part...

Page 21: ...18 Explosion Drawing EGG 48S...

Page 22: ...ront panel 1 10 big steel foot 4 11 thermocouple 4 12 igniter pin with wire 4 13 U shape burner 4 14 thermocouple fixation plate 4 15 body shell 1 16 chimney 1 17 angle connector 4 18 sabaf gas valve...