Installation drawings
4. Attention
4.1 The area where the appliance is installed and the body of the appliance must be kept clear of
combustibles and flammables. This includes mops, rags, grease, wrapping paper and
electric cords. Failure to comply with this may cause fire.
4.2 For complete shutdown of this appliance after using, turn all gas control valves to the “OFF”
position immediately.
4.3 Smell around the appliance before using. If any unpleasant odor of gas is present, shut down
the appliance at the main gas shut-off valve. Open the window for better ventilation.
Contact the qualified personnel for adjustment and repair. Never attempt to ignite the
appliance.
4.4 For the flow of air required for combustion, need to install the appliance in a suitably
ventilated room in accordance with the regulations in force.
4.5 The appliance should be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room.
4.6 Install the appliance with a clear space of at least 30cm on all sides of the device.
4.7 The maximum cylinder dimensions(regulator included) should not exceed (D)50x(H)105cm
if no cylinder compartment included.
4.8 The tubing or the flexible hose must be changed within the prescribed intervals or with-in
one year. The flexible hose should not extend than 1.5m according to standard EN 16436-1
:
2014+A3
:
2020.
4.9 Install the appliance with a clear space of 30cm on all sides of the device.