6.4 Turn the knob anticlockwise to open the main burner valve, press ignitor to ignite burner. 

”  for  complete  max  flame  of  the  main  burner,  until  “ ”  for  min  flame  of  main 

burner. The flame can be adjusted basing upon the requirements. 

6.5 After using, turn the knob clockwise to the “0” position for complete shutdown of the main 

burner. 

7. Cleaning and Maintenance

7.1 The control panel facial should be cleaned daily.

7.2 If the unit will stay idle for a long time, the stainless steel surface should be rinsed with a 

piece of cloth which is dampened with gasoline. Then place it in a well-ventilated area. 

7.3 Clean the surface with warm soap water solution, and then clean it with clean water. Wipe 

dry  with  a  soft  clean  cloth.  Never  use  a  water  jet.  This  appliance  is  not  water-jet 
approved. 

7.4  Never  use  abrasive  or  acid  detergents,  brushes  or  scrapers  to  clean  the  stainless  steel 

surface. Because the ferrous objects could leave rust stains. Never use the chlorine-based 
products  (such  as  hydrochloric  acid  or  bleach)  to  clean  the  surface,  even  though  these 
detergents have been diluted. The cleaning should be done in the same direction as the 
satin finish. 

7.5 The main burners should be cleaned periodically. (Once a week) 

8. Transportation and Storage

The appliance should be placed carefully and it should never be put upside down during the 
transportation  period.  The  packed  unit  should  be put  in  a  well-ventilated environment  free 
from  the  corrosive  atmosphere.  If  it  is  temporarily  stored,  a  rain-proof  measure  should  be 
taken.   

Exploded Diagram & Part List 

Summary of Contents for NRC-580

Page 1: ...NRC 580 Gas hokker stove USER S MANUAL...

Page 2: ...TABLE OF CONTENTS 1 Structure and General Performance 2 Specifications 3 Installation 4 Attention 5 Gas Connection 6 Operation 7 Cleaning and Maintenance 8 Transportation and Storage...

Page 3: ...only Any improper adjustments or service may cause personal injury or property damage WARNING This appliance must be operated by a professionally trained cook NRC 580 is developed and designed by our...

Page 4: ...6mm 20mbar 10kW 1058l hr 3 1kW 328l hr G25 3 2 6mm 25mbar 9 6kW 1155l hr 2 4kW 289l hr Notice Size of the pan The biggest pan for open burner is 550mm The smallest pan for open burner is 230mm 3 Insta...

Page 5: ...t to ignite the appliance 4 4 For the flow of air required for combustion need to install the appliance in a suitably ventilated room in accordance with the regulations in force 4 5 The appliance shou...

Page 6: ...nstalled upstream of gas supply of the appliance where it is within the easy reach of the operator 5 2 Verify fuel gas type If the available fuel does not match the said specification please do not co...

Page 7: ...lean water Wipe dry with a soft clean cloth Never use a water jet This appliance is not water jet approved 7 4 Never use abrasive or acid detergents brushes or scrapers to clean the stainless steel su...

Page 8: ......

Page 9: ...pressure valve 1 6 rear foot 1 7 Framework 1 8 front foot 1 9 foot base 1 10 control panel 4 11 knob 1 12 knob insert 1 13 ignitor 1 14 gas inlet pipe 1 15 gas valve 1 16 angle connector 1 17 pipe 1 1...

Page 10: ...ve Model NRC 580 Imported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Brand ADEXA Application of Council Directive s EU 2016 426 9 March 2016 Stand...

Page 11: ...ported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Brand ADEXA Application of Council Directive s EU 2016 426 2018 No 389 UK SI 2019 696 2019 No 12...

Reviews: