3. Safety Cautions

1)  This  unit  uses  AC220V/60Hz  power,  there  should  be  a  500va 
stabilizer if the voltage  fluctuation exceed AC198V

264V

2)   The user should hold the plug when the power is on/off, dragging or 
pulling the power   cord is prohibited. 
3)   Do not remove the power cord or plug
4)    Must  use  dependent  socket  and  reliable  ground  wire.  Ground  wire 
must not connect with the null line of the gas pipe, warm gas pipe, water 
pipe and must be single power
5)  Never splash water on the unit directly.
6)  Keep  away  from  explosive,  hazardous  goods  such  as  ether,  gas, 
alcohol, bonding agents,      gunpowder etc. 
7)  Keep  away  from  spray  of  inflammables  such  as  paints,  coating 
materials etc. 
8)    After  the  unit  is  switched  off,  it  should  not  be  restarted  within  5 
minutes.
9)  Do not leave the power cord under any heavy objects including the 
unit itself. 
10)  Do not drill holes or install other objects on the casing. 
11)  This cooler is not suitable for storage pharmaceutical products.

4. Portage and storage

1)    Keep  the  unit  vertical  when  carrying  the  unit,  the  angle  to  the 

  °

horizontal  line  should  not  be  over  50

otherwise  it  will  damage  the 

compressor and affect normal operation of the unit. 
2)   The  unit  should  be  place  on  a  solid  and  firm  ground,  take  away  the 
bottom pack to lower  the shock and noise. 
3)  Leave at least 20 cm of distance between the back of the unit and the 

 °

wall for ventilation  and leave a space with an open angle of 160  for the 
door.
4)  Keep the unit away from heat sources and avoiding direct sunlight.
5)  Never place the unit on a location where water can reach or with high 
moisture. Splashed  water and dirt should be wiped off in time by using 
a soft cloth.
6)  Do not place the unit in the environment cold enough to be iced.

5. Preparation

1)    Remove  the  carton  and  packing  foam  (including  the  bottom  foam) 
before using.
2)  Clean the unit before using.
3)  Adjust  the  foot  to  make  the  unit  steady  according  to  the  ground 

 

Problems

Possible cause

Ways to solve problems

Abnormal operation of
the compressor or has
buzz sound

The power voltage
is out of the rated
range.

Disconnect the power supply
immediately and reconnect
with it after normal voltage. It
is necessary to have a voltage
stabilizer in case of poor
power supply.

Compressor operates
too
long time and no frost
on the surface of inner
cabinet

Refrigeration system
is at fault (leakage or
blocked)

Send the unit to service
department for repair

There is frost or ice
on the evaporator of
the inner cabinet and
too low internal
temperature, the
compressor
operates never stop

Thermostat does not
work

Ask service department for
repair

Bad heat issipation
and ventilation of
casing, the ambient
temperature is too
high

Improve ventilation and ower
the ambient mperature.

Too much warm
food was put in at
one time

Take out some food

Door open requently
and long time door
opening

Decrease number and time of
door opening.

The internal
temperature is too high
and the compressor
operates never stop