MECHANICAL DIMENSIONS: 

 

 
                 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                           

 

 

 

Figure 8: Mechanical dimensions scheme for HD67252-A1

 

Summary of Contents for HD67252-A1

Page 1: ...Nopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67502 Modbus RTU Slave www adfweb com Product HD67004 Modbus TCP Master www adfweb com Product HD67505 Modbus TCP Slave For others Gateways Bridges For CAN bus 2 0A and or CAN bus 2 0B to Modbus See also the following links www adfweb com Product HD67011 Modbus RTU Slave www adfwe...

Page 2: ...N POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and se...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a pot...

Page 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 PROFIBUS Slave Document code MN67252_ENG Revision 1 010 Page 4 of 24 EXAMPLE OF CONNECTION ...

Page 5: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 PROFIBUS Slave Document code MN67252_ENG Revision 1 010 Page 5 of 24 CONNECTION SCHEME ...

Page 6: ...tion between NMEA 2000 Power Supply NMEA 2000 PROFIBUS PROFIBUS Power Supply Two directional information between PROFIBUS bus and NMEA 2000 bus Mountable on 35mm Rail DIN Wide power supply input range 8 19V AC or 8 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67252 software on your PC in order to perform the following Define the parameter of the NMEA 2000 ...

Page 7: ...0 PROFIBUS Slave Document code MN67252_ENG Revision 1 010 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 19V AC and 8 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 19V 8V 35V Consumption at 24V DC Device Consumption W VA HD67252 A1 3 5 HD67252 A1 Caution Do not reverse the polarity power ...

Page 8: ...ot two function modes depending on the position of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have ...

Page 9: ...e MN67252_ENG Revision 1 010 Page 9 of 24 LEDS The device has got three LEDs that are used to give information about the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 NMEA 2000 comm Blinks when a NMEA 2000 frame is received OFF 2 Not used OFF OFF 3 Device state Blinks slowly 1Hz Blinks quickly ...

Page 10: ...NMEA 2000 line with a 120Ω resistor it is necessary that the Dip2 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 Here some codes of cable Belden p n 3105A 1x 22WG stranded twisted pairs con...

Page 11: ...nector The pin assignment is defined like in the right figure Here some codes of cables Belden p n 183079A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232C Cable not exceed 15 meters Th...

Page 12: ...52 To configure the Converter use the available software that runs with Windows called SW67252 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67252 the window below appears Fig 2 Figu...

Page 13: ...ch contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable NMEA 2000 PROFIBUS Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate th...

Page 14: ...ere is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67252 checks a...

Page 15: ...Baud Rate the data rate of the NMEA 2000 bus is defined In the field TimeOut Data s a time is defined when this time is elapsed and the data isn t reliable on PROFIBUS side the data will be set to 0xFF If the field Enable Peer to Peer is checked the gateway accepts all the ID that have the PGN inserted in the Receive Frames section In the field ID Device the ID of the NMEA 2000 side is defined The...

Page 16: ...evice that sends the frame is defined If the field Transport Protocol is checked the frame uses Transport Protocol functions If the field Fast Packet is checked the frame uses Fast Packet functions In the field Start Byte the starting byte to start to save is defined This field is valid only when the field Transport Protocol is checked In the field Num Byte the number of consecutive bytes starting...

Page 17: ... field Priority the priority of the frame is defined Number 0 is the highest priority and 7 is the lowest In the field PGN the PGN of the data to be written from PROFIBUS is defined it is a message identifier In the field Source Address the address of the device that sends the frame is defined If the field On Request is checked the PGN is transmitted when a NMEA 2000 request for this PGN is receiv...

Page 18: ...00 PROFIBUS Slave Document code MN67252_ENG Revision 1 010 Page 18 of 24 GSD FILE By pressing the GSD File button from the main window for SW67252 Fig 2 it is possible to save the GSD file for the PROFIBUS side Note When you import the gsd file on your Master PROFIBUS you will have to add all the modules that are present inside it ...

Page 19: ...tions Turn OFF the Device Connect the Null Modem Cable form your PC to the Converter Put Dip2 of Dip Switch A at ON position see FUNCTION MODES section Select the COM port and press the Connect button Turn ON the device Check the Device State LED It must blink quickly see LEDS section Press the Next button Select which operations you want to do Press the Execute update firmware button to start the...

Page 20: ...en you try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one Check if the serial is connected between the PC and the device Try to repeat the operations for the updating If you are using a dongle try with a native COM port or change the dongle Try with another PC Try to restart the PC If you are using the program inside a Virtual M...

Page 21: ...om Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 PROFIBUS Slave Document code MN67252_ENG Revision 1 010 Page 21 of 24 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67252 A1 ...

Page 22: ...ng part number is formed by a valid combination of the following HD67252 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67252 NMEA 2000 PROFIBUS Slave Converter Order Code HD67252 A1 NMEA 2000 PROFIBUS Slave Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 35mm Rail DIN ...

Page 23: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human h...

Page 24: ... to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve m...