background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

Modbus TCP Master / KNX

 

 

Document code: MN67814_ENG     Revision 1.003   Pagina 5 di 27

 

 

 

 

CONNECTION SCHEME: 

 

 

Figure 1: Connection scheme for HD67814-KNX-B2

 

 

Summary of Contents for HD67814-KNX-B2

Page 1: ...com Product HD67804 CANopen www adfweb com Product HD67806 EtherNet IP Master www adfweb com Product HD67807 EtherNet IP www adfweb com Product HD67808 DeviceNet Master www adfweb com Product HD67809...

Page 2: ...DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently u...

Page 3: ...ks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation asse...

Page 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Master KNX Document code MN67814_ENG Revision 1 003 Pagina 4 di 27 EXAMPLE OF...

Page 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Master KNX Document code MN67814_ENG Revision 1 003 Pagina 5 di 27 CONNECTION SCHEME Figure 1 Conn...

Page 6: ...directional information between KNX bus and Modbus TCP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You...

Page 7: ...aster KNX Document code MN67814_ENG Revision 1 003 Pagina 7 di 27 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vma...

Page 8: ...t two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip...

Page 9: ...evice powered OFF Device not powered 2 KNX communication yellow Blinks when KNX frame is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Modbus communication yellow Bl...

Page 10: ...lighting to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Sh...

Page 11: ...TCP communication and for programming the device The Ethernet connection must be made using Connector2 of HD67814 KNX B2 with at least a Category 5E cable The maximum length of the cable should not ex...

Page 12: ...e the available software that runs with Windows called SW67814 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last versi...

Page 13: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable Modbus TCP Master KNX Converter in order to configure...

Page 14: ...re is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Con...

Page 15: ...ield Type the type of KNX is defined fixd to KNX TP In the field ID Device the ID of the KNX side of the converter is defined The means of the fields for the Modbus TCP Master section are In the field...

Page 16: ...ld Source Address the Source Address to assign to the KNX message is defined In the field Dest Group the Group address 2 level structure 3 level structure or free address structure or the device addre...

Page 17: ...s checked the gateway sends the KNX command when the data on Modbus change the value If the field On Timer is checked the gateway sends the KNX command cyclically In the field Poll Time the delay in m...

Page 18: ...bus Read is used to read the data from the Modbus TCP slaves and make them available on KNX network The second part Modbus Write is used to write the data that arrives from the KNX system into the Mod...

Page 19: ...rt the number of consecutive registers to be read In the field Poll Time insert the time to make this request In the field Max Error is the number of errors continues that the gateway waits before sus...

Page 20: ...d Slave ID the address of the Modbus device that you have to write is defined In the field Type insert the data type of the register you would like to write You can choose between the following o Coil...

Page 21: ...he address of the internal array where read the information In the field Start Bit insert the start bit of the first byte of the field Position where start to read the data to write Valid only for the...

Page 22: ...n ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are O...

Page 23: ...ng Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8...

Page 24: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus TCP Master KNX Document code MN67814_ENG Revision 1 003 Pagina 24 di 27 MECHANICAL DIMENSIONS Figure 9 Mechani...

Page 25: ...part number is formed by a valid combination of the following HD67814 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67814 KNX Modbus TC...

Page 26: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicab...

Page 27: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...

Reviews: