background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Client / J1939 

 

Document code: MN67B17_ENG     Revision 1.000    Page 1 of 30

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 
 
 

User Manual 

Revision 1.000 
English 

 

OPC UA Client / J1939 - Converter

 

 

(Order Code: HD67B17-B2) 

 

for Website information:  

http://www.adfweb.com/?Product=HD67B17

    

 

for Price information: 

http://www.adfweb.com/?Price=HD67B17-B2

  

 
 

Benefits and Main Features: 

 

Triple electrical isolation 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

 

For others OPC UA Client devices, see also the following links:  

 
OPC UA Client from/to …

 

www.adfweb.com?Product=HD67B08

  

(

Serial

www.adfweb.com?Product=HD67B09

  

(

Modbus Slave

www.adfweb.com?Product=HD67B10

 

(

Modbus TCP Slave

www.adfweb.com?Product=HD67B11

  

(

BACnet

www.adfweb.com?Product=HD67B12

  

(

CAN

www.adfweb.com?Product=HD67B13

  

(

CANopen

www.adfweb.com?Product=HD67B14

  

(

DeviceNet Slave

www.adfweb.com?Product=HD67B15

  

(

DMX

www.adfweb.com?Product=HD67B16

  

(

EtherNet/IP Slave

www.adfweb.com?Product=HD67B18

  

(

KNX

www.adfweb.com?Product=HD67B19

    

(

MQTT

www.adfweb.com?Product=HD67B20

    

(

NMEA0183

www.adfweb.com?Product=HD67B21

    

(

NMEA2000

www.adfweb.com?Product=HD67B22

    

(

PROFINET

www.adfweb.com?Product=HD67B23

  

(

SNMP Agent

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

User Manual 

Summary of Contents for HD67B17-B2

Page 1: ...to www adfweb com Product HD67B08 Serial www adfweb com Product HD67B09 Modbus Slave www adfweb com Product HD67B10 Modbus TCP Slave www adfweb com Product HD67B11 BACnet www adfweb com Product HD67B12 CAN www adfweb com Product HD67B13 CANopen www adfweb com Product HD67B14 DeviceNet Slave www adfweb com Product HD67B15 DMX www adfweb com Product HD67B16 EtherNet IP Slave www adfweb com Product H...

Page 2: ...NTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 Pagina 2 di 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document...

Page 3: ...s etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potent...

Page 4: ...al Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client J1939 Document code MN67B17_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION ...

Page 5: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client J1939 Document code MN67B17_ENG Revision 1 000 Page 5 of 30 Figure 1 Connection scheme for HD67B17 B2 CONNECTION SCHEME ...

Page 6: ...s in reading and 1500 bytes in writing Two directional information between J1939 and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67B17 software on your PC in order to perform the following Define the parameter of OPC UA Define the parameter of J1939 line Define the list of OPC ...

Page 7: ...Client J1939 Document code MN67B17_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67B17 B2 8V 24V 12V 35V Consumption at 24V DC Device W VA HD67B17 B2 4 Caution Not reverse the polarity power HD67B17 B2 ...

Page 8: ...vice has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Dip1 in On position is used for upload the Project Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functi...

Page 9: ...te Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA response OFF No OPC UA response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 J1939 comm yellow Flashing J1939 communication OFF No J1939 communication Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state yellow ON At least one OPC UA Server is disconnected O...

Page 10: ...Revision 1 000 Page 10 of 30 CAN For terminating the CAN line with a 120Ω resistor it is necessary that the Dip1 of Dip Switch A is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 ...

Page 11: ...The Ethernet connection must be made using Connector3 of HD67B17 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cr...

Page 12: ...use the available software that runs with Windows called SW67B17 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67B17 the window below appears Fig 2 Note It is necessary to have insta...

Page 13: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Client J1939 Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the ...

Page 14: ...e is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67B17 check auto...

Page 15: ...ne 39 0438 30 91 31 User Manual OPC UA Client J1939 Document code MN67B17_ENG Revision 1 000 Page 15 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Page 16: ...ature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be enabled or disabled pressing the Check Box field The means of the fields for J1939 are In the field Baudrate the data rate of J1939 is defined In the field TimeOut Data a time is defined When a J1939 message is ...

Page 17: ...J1939 Document code MN67B17_ENG Revision 1 000 Page 17 of 30 Figure 4 OPC UA Client Access window OPC UA ACCESS By Pressing the OPC UA Client Access button from the main window for SW67B17 Fig 2 the window OPC UA Client Access appears Fig 4 This section is used to define the list of the OPC UA Servers to read write with the OPC UA Client ...

Page 18: ...Page 18 of 30 Figure 5 Add OPC UA Server Figure 6 Modify OPC UA Server By clicking on Add it is possible to add a new OPC UA Server inserting its characteristics Server Address Authorization Security Type The window Add OPC UA Server appears Fig 5 By clicking on Modify it is possible to change these characteristics for the selected Server The window Modify OPC UA Server appears Fig 6 ...

Page 19: ... UA window By clicking on Scan it is possible to get the list of available variables from the selected Server The window Scan Server OPC UA appears Fig 7 The means of the checkboxes inside the table are If the field Read is checked the variable can be read If the field Write is checked the variable can be written Note For each variable it is possible to uncheck these fields and the variable will n...

Page 20: ...If the field Enable is checked the OPC UA variable is enabled In the field Display name the name of the OPC UA variable is defined In the field Node Type the type of the OPC UA node which includes the variable is defined In the field Node ID the name of the OPC UA node which includes the variable is defined In the field Var Type the data format of the OPC UA variable is defined In the field Name S...

Page 21: ...ed In the field Node Type the type of the OPC UA node which includes the variable is defined In the field Node ID the name of the OPC UA node which includes the variable is defined In the field Var Type the data format of the OPC UA variable is defined In the field Name Space Index the Name Space Index of the node which includes the variable is defined If the field On Change is checked the OPC UA ...

Page 22: ...n the starting byte of the internal memory arrays where getting the value is defined In the field Mnemonic a description of the variable is defined Note By clicking on Auto Pos the position of the internal memory arrays where saving getting the value of variable is automatically calculated Note A variable can be added manually in Variables in Read and or Variables in Write sections without scannin...

Page 23: ... of the data of J1939 message is defined it is an identifier In the field Source Address the address of the device that sends the frame is defined If the field Transport Protocol is checked the frame use transport protocol functions used to send more than 8 bytes In the field Start Byte the start byte of the J1939 message to map into the internal memory is defined In the field N Byte the number of...

Page 24: ... is a number among 0 1 2 3 4 5 6 7 The number 0 is the highest priority and 7 is the lowest In the field Data Page the Data Page is defined the value can be 0 or 1 usually it is 0 In the field PGN the PGN of J1939 message is defined it is an identifier In the field Source Address the source address to use to send the frame is defined In the field N Bytes the number of byte of the frame is defined ...

Page 25: ...ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cabl...

Page 26: ... settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prom...

Page 27: ... com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client J1939 Document code MN67B17_ENG Revision 1 000 Page 27 of 30 MECHANICAL DIMENSIONS Figure 14 Mechanical dimensions scheme for HD67B17 B2 ...

Page 28: ...ng part number is formed by a valid combination of the following HD67B17 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B17 OPC UA Client J1939 Converter Order Code HD67B17 B2 OPC UA Client J1939 Converter ACCESSORIES Order Code AC34011 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012 35mm Rail DIN Power Sup...

Page 29: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human heal...

Page 30: ...o exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve mon...

Reviews: