SOFTWARE OPTIONS: 

 

By  pressing  the  “

Settings

”  (

)  button    there  is  the  possibility  to  change  the  language  of  the  software  and  check  the  updatings  for  the 

compositor. 
 
In  the  section  “Language”  it  is  possible  to  change  the  language  of  the 
software. 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
In  the  section  “Connection  Options”,  it  is  possible  to  check  if  there  are  some 
updatings of the software compositor in ADFweb.com website. 
Checking  the  option  “

Check  Software  Update  at  Start  of  Program

”,  the 

SW67D40 check automatically if there are updatings when it is launched.

Summary of Contents for HD67D40-B2

Page 1: ...ster www adfweb com Product HD67D17 BACnet Slave www adfweb com Product HD67D18 Ethernet www adfweb com Product HD67D19 CAN www adfweb com Product HD67D20 CANopen www adfweb com Product HD67D21 DeviceNet Master www adfweb com Product HD67D22 DeviceNet Slave www adfweb com Product HD67D23 DMX www adfweb com Product HD67D24 EtherNet IP Master www adfweb com Product HD67D25 EtherNet IP Slave www adfw...

Page 2: ...HNICAL SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adf...

Page 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inapprop...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN SNMP Manager Document code MN67D40_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION ...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN SNMP Manager Document code MN67D40_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67D40 B2 xxxMHz ...

Page 6: ...tional information between LoRaWAN bus and SNMP bus Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67D40 software on your PC in order to perform the following Define the parameter of LoRaWAN line Define the parameter of SNMP line Define the list of LoRaWAN messages in uplink and downlin...

Page 7: ...G Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA HD67D40 B2 xxxMHz 3 5 HD67D40 B2 xxxMHz Caution Not reverse the polarity power ...

Page 8: ...f the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section...

Page 9: ...e green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 LoRaWAN communication yellow Blinks when LoRaWAN data is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 SNMP communication yellow Blinks when a SNMP response is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state yellow ON An e...

Page 10: ...ar of stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advantage of the Long Range characteristics of the LoRa physical layer allowing a single hop link between the end device and one or many gateways All modes are capable of bi directional communication and there is support for multicast addressing groups to make eff...

Page 11: ...ommunication The Ethernet connection must be made using Connector2 of HD67D40 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC is recommended the use of a...

Page 12: ... Converter use the available software that runs with Windows called SW67D40 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windows XP Vista Seven 8 10 32 64bit When launching the SW67D40 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 Figure 2 Main window for SW67D40 ...

Page 13: ...figuration A device s configuration can also be imported or exported To clone the configurations of a Programmable LoRaWAN SNMP Manager Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another nam...

Page 14: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67D40 check automatically if there are updating...

Page 15: ...LoRaWAN SNMP Manager Document code MN67D40_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Page 16: ...ation is defined In the field Transmission Type the type of LoRaWAN communication is defined In the field Max Payload Size the maximum dimension of the LoRaWAN messages is defined fixed in relation to the data rate selected In the field JoinEUI the ID of the application server is defined In the field Activation Method the method used to join into a LoRaWAN network is defined In the field Device Ad...

Page 17: ...SS the IP address that you want to give to the SNMP side is defined In the field SUBNET Mask the SubNet Mask of the SNMP side is defined In the field GATEWAY the default gateway that you want to use is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Name of Station it is possible to assign a name to the SNMP no...

Page 18: ...he data to SNMP LORAWAN UPLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where taking the data is defined In the field Num Byte the number of consecutive bytes to take from the internal array starting from Start Byte is defined If the field On Change is checked the LoRaWAN message...

Page 19: ...WAN DOWNLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where placing the data is defined In the field Num Byte the number of consecutive bytes to write to the internal array starting from Start Byte is defined In the field Mnemonic a description of the message is defined ...

Page 20: ...efined selectable or editable manually In the field OID the OID to read write from to the SNMP Agent device is defined In the field Type the type of data to read write String or Int is defined In the field Mode the type of SNMP request used Get Set or Trap is defined By checking the field On Change the SNMP request only for Set Mode is made only if EtherCAT data written by the EtherCAT Master are ...

Page 21: ...he user for the SNMP authentication is defined o In the field Auth Pass the password for the SNMP aithentication is defined o In the field Priv Pass the password for Privacy authentication is defined o In the field Security Level the type of security used is defined o In the field Auth Mode the mode used for the authentication is defined o In the field Priv Mode the mode used for Privacy is define...

Page 22: ...net cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cable inserted Insert the actual IP...

Page 23: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d ...

Page 24: ...AN Access section of SW67D40 Example 1 the converter is sending a LoRaWAN message related to row 4 of LoRaWAN Access LoRaWAN Uplink table of LoRaWAN Access section of SW67D40 with a Num Byte set of 4 The data from these 4 bytes is 01 02 03 04 hex The payload of the LoRaWAN message will look like 04 01 02 03 04 where 04 index of the row of LoRaWAN Access LoRaWAN Uplink table 01 02 03 04 data taken ...

Page 25: ...strial Electronic Devices ADFweb com S r l User Manual LoRaWAN SNMP Manager Document code MN67D40_ENG Revision 1 000 Page 25 of 28 Figure 7 Mechanical dimensions scheme for HD67D40 B2 MECHANICAL DIMENSIONS ...

Page 26: ...g HD67D40 B 2 xxxMHz Frequency for LoRaWAN communication 868 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67D40 LoRaWAN SNMP Manager Converter Order Code HD67D40 B2 868MHz LoRaWAN SNMP Manager Converter ACCESSORIES Order Code AC34011 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012 35mm Rail DIN Power Su...

Page 27: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be cau...

Page 28: ...o the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or excha...

Reviews: