background image

 

21                  

 

 

 

 

Warranty Certificate 

 

Reseller’s name: 

Model:________________________________

Serial number:_____________________

 

 
Sold to: ___________________________________________________ in: _____/_____/_____ 

Address: ______________________________________________________________________ 

Postal Code: _______-____Tel: _______________Email: ________________________________ 

 

 

 

 

 

 

 

 

 

_____________________________ 

                 Client Signature 

 

Note:

 The Warranty is limited to the replacement / repair by ADF or its agent of the components 

known to be defective and excludes any other type of coverage or compensation such as the costs 

of transportation, removal or reinstallation of the equipment.  

 

ATTENTION 

When the equipment is delivered, please check it. 

The warranty only covers damage caused during transportation if notice was given and marked on 

the document acknowledging receipt of the device within 24 hours. 

 

 

 

 

 

 

Reseller’s stamp 

 

 

 

 

 

_______________________ 

Summary of Contents for ADH100DL

Page 1: ...d by Castworks Pty Ltd 12 Fiveways Boulevard Keysborough VIC 3173 TESTED IN ACCORDANCE WITH AS NZS 4012 2014 AS NZS 4013 2014 Please read this manual thoroughly before installing and starting your fre...

Page 2: ...cal Specifications 06 4 Installation Instructions 09 Flue Outlet 12 5 Fan 13 6 Installing the bricks and baffles 15 7 Instructions for use 16 8 Maintenance and cleaning 18 9 Troubleshooting 20 10 Warr...

Page 3: ...om the sun and transform it into chemical energy The trapped energy e g in the form of wood pellets coal are called biomass fuels and can be converted into various forms electricity fuel or heat Bioma...

Page 4: ...entilated Generally green wood should be left to season for two years Wood to Avoid Softwoods and low density wood This kind of firewood release a lot of heat but burn too quickly and projects embers...

Page 5: ...e both the doors 5 Secondary convection outlet hot air distribution for ducting Inbuilt only 6 Smoke Outlet Flue collar 200mm 8 Crimped 7 Convection inlet Important o The compartment below the combust...

Page 6: ...Factor g kg 1 1 Maximum firewood load kg 10 Minimum clearance distances from combustible materials mm See page 10 Flue Diameter mm 200 Recommended Fuel Burn only Harwood Moisture 20 Electrical Specifi...

Page 7: ...air must be supplied to the room with the heater a minimum equivalent to half the cross sectional area of the flue ie 160cm2 free air o Follow the clearances to combustible materials as shown on page...

Page 8: ...DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING o WARNING DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION CLEARANCES o WARNING WHEN OPERATING THIS APPL...

Page 9: ...flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vertical The Flue terminal must meet the minimum height and external clearances for the flue...

Page 10: ...r glass is 350mm The side clearance to the side of the heater is 150mm to combustibles ie island bench or log storage or similar The clearances to combustibles in front of either glass door is 1200mm...

Page 11: ...d in the room is a solid 10 decorative flue shield The heater must have its own dedicated flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vert...

Page 12: ...so be as high as any nearby structure within a 6m Radius AS 2918 2018 External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with...

Page 13: ...the base will need a custom designed fan cut out in the bench with air supply to each fan below the heater base A cable will need to run from the heater to a wall mount controller the 240V power supp...

Page 14: ...ystem is well dimensioned ensuring proper drainage and that it complies with the Australian standards in force so that there is no undue smoke escape into the surrounding space Keep combustible and fl...

Page 15: ...he central one across the middle on the side bricks and the outer C channel support bars 6 front and back Begin with the side baffle bricks resting on the side bricks then insert the middle brick and...

Page 16: ...resting against each other to allow maximum air flow around the wood and so the kindling doesn t collapse Use about 1kg of split small logs of dry wood 5 Keep the door slightly open allowing the amoun...

Page 17: ...ng smoke or even flame out into the room Excessive combustion does not necessarily translate into more heating power nor into an increase of efficiency Furnacing may also cause irreparable damage to t...

Page 18: ...a small fire initially and keep windows open for ventilation o Clean the chimney and the flame baffle at least once a year using a qualified technician if necessary o Periodically check and replace th...

Page 19: ...burn Wet or green firewood Dirty or clogged chimney Insufficient firewood Use dry wood Clean the chimney Very fast burning Low density firewood Poorly adjusted door Filling cord consumed Load the sto...

Page 20: ...od 2 The complaint must be presented and validated by one of our agents and endorsed by ADF 3 The installation use and maintenance conditions described in this manual have been strictly respected and...

Page 21: ..._____________________________ Client Signature Note The Warranty is limited to the replacement repair by ADF or its agent of the components known to be defective and excludes any other type of coverag...

Page 22: ...2014 AS NZS 4013 2014 Burning Hardwood Maximum Avearge Heat Output kW 18 9 Overall Average Efficiency 60 Particulate Emission Factor g kg 1 1 Maximum firewood load kg 12 Minimum clearance distances f...