EDM Serial-to-Ethernet Converters
User Guide ver. 2.0 | 2021-09-01
Phone: +420 538 890 720
12
E-mail: info@adgt.cz
Configuring converter parameters
1.
Launch the browser and go to the device configuration page by IP-address 192.168.88.1, after
which the authorization window will open.
2.
Enter your username and password to enter the web interface. Default authorization data are:
username – adgt
password –
adgt
After the successful authorization, the main page of the web interface with the current settings of
the device will appear in the browser window.
3.
In the Network menu, configure the Ethernet network settings and save changes using
Submit button.
Table 5. Network settings.
Parameter
Default value
Possible values
MAC-address
Use factory
Use factory - indicated on the sticker of the case
Set manually
IP-address
192.168.88.1
Use the following IP address - static address,
default one or manually entered one
Obtain automatically - from DHCP-server
Subnet mask
255.255.255.0
Default gateway
0.0.0.0
DNS server address
0.0.0.0
Attention! After three incorrect attempts to enter a username / password, access to the device will
be blocked for 30 seconds.
NOTES:
You can set a new password in the General settings menu.
If the current settings of the device are unknown, it is necessary to reset the settings to the
factory values (see
Fig. 8. Converter EDM106. Main page of web interface.