background image

 

Applied Digital, Inc. 19315 Hwy 413   Branson West, MO 65737 

417-297-0361 F816-337-3398 web:www.appdig.com e-mail:adiinfo@appdig.com 

T-Max® 3W G2 User’s Guide

   

 

 

 

 

 

 

 

 

 

 

 

           

 

 

 

  

 

 

 

 Supplied Components 

 

 

 

 

 

 

 

Specifications

 

 

 

 

 

1, T -Max® 3W G2 Interface T imer 

 

Powe r Supply 

9-12 VDC or AC @ 300mA 

1, 9VDC or AC Power Supply 

 

Dime nsions 

Cover Plate: 5.25” x 5.25” 

1, T -Max® 3W G2 User’s Guide 

 

 

PCB: 2.5” x 3.25” x 1.5” 

1, 50’ Modular Cable with RJ-22 connectors on both ends 

 

Re lay 

220V @5A SPST  

Physical Connections 

Connect the two wires from the tanning bed, for attaching to an external timer, to the “contact” screw terminals on the T-Max® 3W G2. 

Note: 

There may be many wires visible on the tanning bed. Two of these wires are specifically used for connecting the tanning bed to an external 

timer. If you are not sure which two wires to use, refer to the tanning bed’s manual or contact the tanning bed’s manufacturer.  

Connect the 9V @ 300mA transformer to the screw terminal labeled “PWR IN 9-12V” on the back of the T-Max® 3W G2.  Plug the transformer into a 
120VAC outlet. 

Initial configuration 

When power is first applied to the timer the display may show a 99. Press and release the Start/stop button and the display will flash 88. Press and 
release the Up button and the flashing 88 will stop. The timer is now ready to be used as a stand alone timer. 

Setting Parameters 

Note:

 If you are using a T-Max® Manager or T-Max® Manager/Pro and multiple T-Max® 3W G2s, remove power from the T-Max® Manager or Pro. 

Keep power removed from the T-Max® Manager or Pro until all parameter changes are complete. 

1) Apply power to the T-Max® 3W G2 

2) Press and hold the Start/Stop and Up buttons together on the T-Max® 3W G2 until a “P-” appears on the display. Release the buttons. Once the 
buttons are released the display will read a .1 (point one). 

3) Press the Up and Down Buttons until the parameter number that you want is displayed. 

4) Press the Start/Stop Button to observe the current value for that parameter. 

The Display will show a number with a period in the lower center of the display. The numbers will be flashing. The number shown is the current value 
for that parameter. 

For Lamp Hours, Session Counts, etc. the value displayed can be as high as 9999. To display this value, the T-Max® 3W G2 will flash two numbers-
three times, then two numbers-three times, pause, two numbers-three times, two numbers-three times, pause, etc. For example, if you are checking 
lamp hours (Parameter 6) and the display flashes the numbers 53 three times, then 14 three times, pauses then repeats, then the total lamp hours stored 
in that T-Max® 3W G2 is 5314. 

5) Press the Up or the Down button to change the parameter to the desired value. 

If you want to clear the value for that parameter, press the Up and Down buttons at the same time until the display flashes “0.0”.  

6) Press the Start/Stop Button. 

The display will show the parameter number you just changed and a solid period in the lower center of the display. You may now change another 
parameter by pressing the Up and Down buttons until the parameter you want displayed. Repeat Steps 2-4. 

7) To exit the Parameter mode press and hold the Up and Down buttons together until the period goes away. 

Parameter Numbers for Observing and Changing Parameters.

 

Parm   De scription 

Max    

De fa
ult 

Note s 

Address 

255 

254 

Address of T -Max® 3W G2 

Beep Mode 

Used for High Power beds. 0=Alarm only, 1=Alarm and Flip 

Delay T ime 

10 

Delay in minutes stored in the T -Max® 3W G2. 

Session Counts 

65535 

T otal session counts for T -Max® 3W G2s. 

Lamp Hours 

65535 

Bulb hours for each bed. 

Bed Hours 

65535 

Number of hours a bed is on. 

Manual Session Counts 

65535 

Counts the number of sessions the T -Max® 3W G2 has run while in Stand Alone Mode 

Clean Room 

0 = Clean Room Disabled, 1 = Enabled 

10* 

Manual Lockout 

0 = Stand Alone Enabled, 1 = Disabled 

13 

Cool Down Mode 

10 

0 = Disabled, 1-10=Enabled. T ime delay in minutes allowing bed to cool.   

15 

Fixed Session Counts 

65535 

Counts number of sessions ran through the T -Max® 3W G2. T his value cannot be changed at all. Used as 
point of reference. 

20 

External Speaker 

0 = Speaker on T -Max® 3W G2, 1 = External Speaker will be used. 

21 

Pause Mode 

0 = When session is paused, time will continue to count down. 1 = When session is paused, session time will 
stop counting down. 

22 

Auto Bed Shut Off 

For T -Max® Intercom Systems Only. 0 = When timer is called bed will stay on, 1 = When timer is called, bed 
will stuff off automatically. 

24 

Max Address 

0 = T he T -Max® 3W G2 will only go to address 99. 1 = T -Max® 3W G2 will go to address 128. 

25 

Start/Stop Clean Room 
Clear 

0 = Only the Set button can be used to clear the Clean Room. 1 = Either the Set or the Start/Stop button can 
be used to clear the clean room. 

 

IN-ROOM SINGLE BED CONTROL 

 

Running a session  

Press the Up or the Down Button on the T-Max® 3W G2 until the session time is displayed. If the display shows a 0, and you want to go directly to 
the maximum time, press the down button once. Press and release the Start/Stop button to start the session. If a delay other than 0 is entered, the 
delay will count down. A period on the lower right corner of the display will flash rapidly. When the session starts, the period will flash at a once per 
second rate. If you want to energize the tanning bed before the delay time expires, press and release the Start/Stop button again. 

To pause a session, press the Start/Stop button on the T-Max® 3W G2. The flashing period on the lower right corner of the display will stop flashing. 
The tanning unit will de-energize. Press the Start/Stop button on the T-Max® 3W G2 to re-start the session. The period on the lower right corner of 
the display will resume flashing. The tanning unit should re-energize. 