background image

7

ADICOS GSME-X20

408-2410-004 EN22

sAfety instructions

2.3  Personnel Qualification

Any work on ADICOS systems may only be performed by qualified personnel. Per

-

sons, who can perform work on electrical systems and recognize possible dan

-

gers based on their professional education, knowledge, and experience as well as 

knowledge of the applicable provisions, are considered qualified personnel.

WARNING!

Personal injury and property damage!

 

Improperly performed work on and with the device can lead to malfuctions.

• 

Installation, startup, parameterization and maintenance may be performed 

only by authorized and properly trained personnel.

2.4 

Handling Electrical Voltage

DANGER!

Risk of explosion by electrical voltage in potentially explosive atmospheres!

The electronics of ADICOS GSME-X20 detectors requires an electrical voltage 

that can trigger an explosion in potentially explosive atmospheres.

•  Do not open enclosure!
• 

De-energize the entire detector system and secure against unintentionally 

reactivation for all wiring work!

2.5 

Modifications

WARNING!

Property damage or detector failure by any form of unauthorized 

modification!

Any form of unauthorized modification or extension can lead to a failure of the 

detector system. The warranty claim expires.

• 

Never make unauthorized modifications on your own authority. 

2.6 

Accessories and Spare Parts

WARNING!

Property damage due to short circuit or failure of the detector system

The use of parts other than the manufacturer's original spare parts and original 

accessories may result in property damage due to short circuits.

• 

Only use original spare parts and original accessories!

• 

Original spare parts and accessories may only be installed by trained spe

-

cialist personnel.

• 

Qualified personnel are persons as described in Chap. 2.3

Summary of Contents for GSME-X20

Page 1: ...dustrieelektronik GmbH Helmholtzstr 21 38 40 41747 Viersen Germany 49 2162 3703 0 info gte de GSME X20 Supplementary Instruction Manual for GSME X20 Fire Gas Detector IP64 DO NOT OPEN IN GAS LOADED AT...

Page 2: ...oltzstr 21 38 40 41747 Viersen GERMANY Support hotline 49 2162 3703 0 E Mail support adicos gte de 2023 GTE Industrieelektronik GmbH This document and all figures contained may not be copied changed o...

Page 3: ...for fire gas detection in industrial environments and already in the incipient stage With the ADICOS software all detector states and concentration curves can be displayed graphically Sensitivities as...

Page 4: ...6 2 3 Personnel Qualification 7 2 4 Handling Electrical Voltage 7 2 5 Modifications 7 2 6 Accessories and Spare Parts 7 3 Structure 8 3 1 Overview 8 3 2 Cable assignment 8 3 3 Display elements 9 4 In...

Page 5: ...notes are used through this manual DANGER This combination of symbol and signal word indicates an immediately dangerous situation that will lead to death or severe injuries if not avoided WARNING This...

Page 6: ...l Data must be met Any deviating use requires prior consultation with the manufacturer Compliance with this manual as well as all applicable country specific provisions is also part of the intended us...

Page 7: ...ectors requires an electrical voltage that can trigger an explosion in potentially explosive atmospheres Do not open enclosure De energize the entire detector system and secure against unintentionally...

Page 8: ...gland 3 2 Cable assignment Wire Color Signal Signal limit contact 1 black Operating voltage 21 6 40 V DC non polarized 1 white 2 black Relay output X6 e Alarm NO1 2 white Relay output X6 a Alarm NO1 3...

Page 9: ...lack NO 6 white C 3 3 Display elements Signal Dome The signal dome is a translucent element It includes the status LED to indicate the operating condition of the X20 detectors The light signals of the...

Page 10: ...explosion due to electrical voltage in hazardous areas The electronics of ADICOS GSME X20 works with an electrical voltage that can trigger an explosion in potentially explosive atmospheres Do not ope...

Page 11: ...x protected connection boxes with respective approval Do not bend connection cable Observe minimum bending radius Chap 9 Technical Data 5 Commissioning DANGER Risk of explosion due to electrical volta...

Page 12: ...plosion in potentially explosive atmospheres Do not open enclosure De energize the entire detector system and secure against unintentionally reactivation for all wiring work Replace the closed detecto...

Page 13: ...power consumption with heating VA 14 M Bus voltage signal V mA max 40 V non polarized max 30 mA Thermal physical data Ambient Temperature C 20 50 C Relative humidity 95 non condensing Sensor data Sens...

Page 14: ...able YR Year of production variable ART Nr Article number variable TEMP Ambient temperature IP Degree of protection COM Nr Communication number variabel VDC VA Voltage range maximum pow er consumption...

Page 15: ...15 ADICOS GSME X20 408 2410 004 EN22 Appendix 10 Appendix 10 1 ADICOS Mounting Plate A A 1 5 0 1 5 0 1 3 0 1 3 0 6 4 A A...

Page 16: ......

Reviews: